首页> 外文期刊>ASHRAE Transactions >Real-Time Optimization of Energy Efficiency for Cold Climate Heat Pumps with Extremum Seeking Control
【24h】

Real-Time Optimization of Energy Efficiency for Cold Climate Heat Pumps with Extremum Seeking Control

机译:极值搜索控制的冷气候热泵能效的实时优化

获取原文
获取原文并翻译 | 示例

摘要

Optimizing energy efficiency in real-time operation is a critical issue for cold-climate beat pump systems, while model based control/ optimisation strategies may involve costly modeling and calibration. As a model-free control strategy, extremum seeking control has been applied to optimize the operational efficiency for three configrations: internal heat exchanger cycle vapor injection, flash tank vapor injection and cascade heat pump. Simulation studies validate the effectiveness of the control strategy.