首页> 外文期刊>IEEE Transactions on Applied Superconductivity >Test results of the prototype combined sextupole-dipole corrector magnet for LHC
【24h】

Test results of the prototype combined sextupole-dipole corrector magnet for LHC

机译:用于LHC的原型六极-偶极校正磁体组合的测试结果

获取原文
获取原文并翻译 | 示例

摘要

The corrector magnet for the Large Hadron Collider (LHC) contains a 1.5-T dipole for orbit correction and a 8000 T/m/sup 2/ sextupole for chromaticity correction. The dipole has for compactness been mounted around the sextupole coil. A full-scale prototype of 1.3-m length has been fabricated and tested. The coils were first tested at 4.2 K. It appeared that the training of the impregnated coils could be strongly reduced by increasing the radial precompression. The coils were subsequently cooled to the operational temperature between 1.8 and 2 K and the field quality was measured with a harmonic rotating coil. The results of the tests show that the combined dipole-sextupole corrector magnet does meet the desired field strengths.
机译:大型强子对撞机(LHC)的校正磁铁包含一个1.5-T偶极子用于轨道校正,一个8000 T / m / sup 2 /六极子用于色度校正。为了紧凑,偶极子被安装在六极子线圈周围。已经制造并测试了长度为1.3米的完整原型。线圈首先在4.2 K下进行测试。似乎可以通过增加径向预压缩来大大减少对浸渍线圈的训练。随后将线圈冷却到1.8到2 K之间的工作温度,并用谐波旋转线圈测量磁场质量。测试结果表明,组合的偶极-超极校正器磁体确实满足所需的场强。