首页> 外文期刊>IEEE Transactions on Applied Superconductivity >Slotted high-T/sub c/ dc SQUID magnetometers
【24h】

Slotted high-T/sub c/ dc SQUID magnetometers

机译:开槽高T / sub c / dc SQUID磁力计

获取原文
获取原文并翻译 | 示例

摘要

Recently, it was observed that the low frequency noise of slotted SQUIDs is not affected when cooling them down in magnetic fields up to 0.05 mT. This behavior is ascribed to the fact that magnetic vortices are expelled out of the narrow strips into the slots. Thus 1/f noise by hopping of vortices in the superconducting structure is eliminated. Here we present a systematic investigation on a series of slotted high-T/sub c/ dc SQUIDs. The number of slots varies from zero to eight. A model is developed that provides values for the effective area and inductance of the slotted washers and the current distribution within the slotted SQUIDs. The model can explain the experimentally observed maximum in the effective area for four slots very well. The observed agreement with respect to the modulation depth supports the theoretical values for the inductance. The white noise of the slotted SQUIDs is higher than expected, while the expected rise of low frequency noise for field cooled solid washer SQUIDs was not observed.
机译:最近,观察到开槽的SQUID的低频噪声在高达0.05 mT的磁场中冷却时不受影响。这种现象归因于这样的事实,即磁涡流从窄条中喷出到狭缝中。因此,消除了超导结构中因跳动而产生的1 / f噪声。在这里,我们对一系列开槽的高T / sub c / dc SQUID进行了系统的研究。插槽的数量从零到八个不等。开发了一个模型,该模型提供了开槽垫圈的有效面积和电感以及开槽的SQUID内的电流分布的值。该模型可以很好地解释四个插槽在有效区域中的实验观察到的最大值。所观察到的关于调制深度的一致性支持了电感的理论值。开槽的SQUID的白噪声高于预期,而未观察到现场冷却的固态洗衣机SQUID的低频噪声的预期上升。