首页> 外文期刊>IEEE Transactions on Applied Superconductivity >A study on mitigation method of perpendicular magnetic field in HTS superconducting coils for power transformer
【24h】

A study on mitigation method of perpendicular magnetic field in HTS superconducting coils for power transformer

机译:电力变压器高温超导线圈中垂直磁场的缓解方法研究

获取原文
获取原文并翻译 | 示例

摘要

Methods to mitigate a perpendicular magnetic field component on the surface of a high temperature superconducting (HTS) tape in HTS coils by arranging low current density (LCD) coils in the edges were studied analytically. Four types of winding arrangement with and without the LCD coils at both edges of the superconducting winding, which are used to model a three-phase 40 MVA HTS transformer, were proposed. The results of magnetic field analysis in the proposed winding arrangements reveal that (1) the maximum perpendicular magnetic field (B⊥max) on the surface of the HTS tape is influenced markedly by the LCD coils arrangements and that (2) the winding arrangement which is LCD coils installed in both edges of top and bottom in the LV and the HV winding is very effective in reducing the B⊥max in both edges of top and bottom.
机译:通过分析研究了通过在边缘布置低电流密度(LCD)线圈来减轻HTS线圈中高温超导(HTS)带表面上垂直磁场分量的方法。提出了四种类型的绕组布置,分别在超导绕组的两个边缘带有和不带有LCD线圈,用于建模三相40 MVA HTS变压器。所提出的绕组布置中的磁场分析结果表明,(1)HTS带表面上的最大垂直磁场(B⊥max)受到LCD线圈布置的显着影响,以及(2)绕组布置LCD线圈安装在LV顶部和底部的两个边缘,而HV绕组对于降低顶部和底部的两个边缘的B⊥max非常有效。