首页> 外文期刊>Applied Superconductivity, IEEE Transactions on >Influence of Mechanical Vibration and Losses Under AC Operating in Bi-2223 Tapes With Ionic Liquid Impregnation
【24h】

Influence of Mechanical Vibration and Losses Under AC Operating in Bi-2223 Tapes With Ionic Liquid Impregnation

机译:离子液体浸渍Bi-2223胶带在交流电下的机械振动和损耗的影响

获取原文
获取原文并翻译 | 示例

摘要

Mechanical loss in superconducting coils is one of the important parameters for the stability of high temperature superconducting coils (HTS coil). We prepared three kinds of impregnations (no impregnation, ionic liquid grease), measured the AC loss of the Bi-2223 tape under DC magnetic field in liquid nitrogen and quantitatively estimated the relation between the impregnation and losses. As a result, the loss can be reduced about 40% by using ionic liquid compared with no impregnation.
机译:超导线圈的机械损耗是高温超导线圈(HTS线圈)稳定性的重要参数之一。我们准备了三种浸渍方法(无浸渍,离子液体油脂),在液氮中的直流磁场下测量Bi-2223胶带的交流损耗,并定量估计了浸渍与损耗之间的关系。结果,与不浸渍相比,通过使用离子液体可以将损失减少约40%。