Validation of PTV margin for Gamma Knife Icon frameless treatment using a PseudoPatient® Prime anthropomorphic phantom

机译:使用PseudoPatient®Prime拟人幻影验证伽马刀图标无框治疗PTV余量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The Gamma Knife Icon allows the treatment of brain tumors mask‐based single‐fraction or fractionated treatment schemes. In clinic, uniform axial expansion of 1 mm around the gross tumor volume (GTV) and a 1.5 mm expansion in the superior and inferior directions are used to generate the planning target volume (PTV). The purpose of the study was to validate this margin scheme with two clinical scenarios: (a) the patient’s head remaining right below the high‐definition motion management (HDMM) threshold, and (b) frequent treatment interruptions followed by plan adaptation induced by large pitch head motion. A remote‐controlled head assembly was used to control the motion of a PseudoPatient® Prime head phantom; for dosimetric evaluations, an ionization chamber, EBT3 films, and polymer gels were used. These measurements were compared with those from the Gamma Knife plan. For the absolute dose measurements using an ionization chamber, the percentage differences for both targets were less than 3.0% for all scenarios, which was within the expected tolerance. For the film measurements, the two‐dimensional (2D) gamma index with a 2%/2 mm criterion showed the passing rates of ≥87% in all scenarios except the scenario 1. The results of Gel measurements showed that GTV (D100) was covered by the prescription dose and PTV (D95) was well above the planned dose by up to 5.6% and the largest geometric PTV offset was 0.8 mm for all scenarios. In conclusion, the current margin scheme with HDMM setting is adequate for a typical patient’s intrafractional motion.
机译:伽马刀图标允许治疗脑肿瘤的掩模基础的单级分数或分级处理方案。在临床上,围绕肿瘤大量(GTV)围绕1mm的均匀轴向膨胀和上下方向的1.5毫米膨胀用于产生规划目标体积(PTV)。该研究的目的是用两个临床情景验证这个保证金方案:(a)患者的头部剩下低于高清运动管理(HDMM)阈值,(b)频繁处理中断,然后由大型诱导的计划适应沥青头动作。遥控头组件用于控制Pseudopatient®Prime头体模的运动;对于剂量测定,使用电离室,EBT3膜和聚合物凝胶。将这些测量与来自伽马刀计划的比较进行了比较。对于使用电离室的绝对剂量测量,所有场景的靶标的百分比差异小于3.0%,这在预期的耐受范围内。对于薄膜测量,具有2%/ 2mm标准的二维(2D)伽马索引显示,除了场景1.除了场景之外的所有场景中的通过率≥87%。凝胶测量结果表明GTV(D100)是由处方剂量和PTV(D95)覆盖良好,高达5.6%,所有场景的最大几何PTV偏移量为0.8mm。总之,具有HDMM设置的当前保证金方案适用于典型的患者的兴奋运动。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号