首页> 美国卫生研究院文献>Anesthesia Progress >A Case of Successful Tracheal Tube Exchange With McGrath MAC for Tube Damage During Oral Surgery
【2h】

A Case of Successful Tracheal Tube Exchange With McGrath MAC for Tube Damage During Oral Surgery

机译:在口腔手术期间与McGrath MAC成功气管莫克拉管损伤的情况

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A patient undergoing a bilateral sagittal split and LeFort 1 maxillary osteotomy performed under general anesthesia required emergent intraoperative exchange of a potentially damaged nasotracheal tube. This exchange was smoothly performed under constant indirect visualization using the McGrath MAC video laryngoscopy system. After the exchange, ventilation of the patient dramatically improved. The removed endotracheal tube was torn 19 cm from the distal tip. The McGrath MAC was useful for visualizing the glottis and confirming the entire course of the tube exchange despite the patient's having a difficult airway (Cormack-Lehane grade 3).
机译:在全身麻醉下进行的患者进行双侧矢状分裂和lefort 1上颌截骨术,所需的眶内鼻腔鼻外膜术后交换。使用McGrath Mac视频喉镜系统在恒定间接可视化下平滑地执行此交换。交换后,患者的通风显着改善。除去的气管内部气管管从远端尖端撕裂19厘米。 McGrath MAC对于可视化的光泽并确认管交换的整个过程,尽管患者具有困难的气道(Cormack-Lehane 3级)。