首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Rapid Detection of Isoniazid Resistance in Mycobacterium tuberculosis Isolates by Use of Real-Time-PCR-Based Melting Curve Analysis
【2h】

Rapid Detection of Isoniazid Resistance in Mycobacterium tuberculosis Isolates by Use of Real-Time-PCR-Based Melting Curve Analysis

机译:基于实时PCR的熔解曲线分析快速检测结核分枝杆菌中异烟肼的耐药性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The MeltPro TB/INH assay, recently approved by the Chinese Food and Drug Administration, is a closed-tube, dual-color, melting curve analysis-based, real-time PCR test specially designed to detect 30 isoniazid (INH) resistance mutations in katG position 315 (katG 315), the inhA promoter (positions −17 to −8), inhA position 94, and the ahpC promoter (positions −44 to −30 and −15 to 3) of Mycobacterium tuberculosis. Here we evaluated both the analytical performance and clinical performance of this assay. Analytical studies with corresponding panels demonstrated that the accuracy for detection of different mutation types (10 wild-type samples and 12 mutant type samples), the limit of detection (2 × 103 to 2 × 104 bacilli/ml), reproducibility (standard deviation [SD], <0.4°C), and the lowest heteroresistance level (40%) all met the parameters preset by the kit. The assay could be run on five types of real-time PCR machines, with the shortest running time (105 min) obtained with the LightCycler 480 II. Clinical studies enrolled 1,096 clinical isolates collected from three geographically different tuberculosis centers, including 437 INH-resistant isolates and 659 INH-susceptible isolates characterized by traditional drug susceptibility testing on Löwenstein-Jensen solid medium. The clinical sensitivity and specificity of the MeltPro TB/INH assay were 90.8% and 96.4%, respectively. DNA sequencing analysis showed that, except for the 5 mutants outside the detection range of the MeltPro assay, a concordance rate between the two methods of 99.1% (457/461) was obtained. Among the 26 mutation types detected, katG S315T (AGC→ACC), inhA −15C→T, katG S315N (AGC→AAC), and ahpC promoter −10C→T accounted for more than 90%. Overall, the MeltPro TB/INH assay represents a reliable and rapid tool for the detection of INH resistance in clinical isolates.
机译:MeltPro TB / INH测定法是最近由中国食品药品监督管理局批准的一项封闭,双色,基于熔解曲线分析的实时PCR检测方法,专门用于检测30个异烟肼(INH)耐药突变。结核分枝杆菌的katG位置315(katG 315),inhA启动子(位置-17至-8),inhA位置94和ahpC启动子(位置1-444至-30和-15至3)。在这里,我们评估了该测定法的分析性能和临床性能。与相应小组的分析研究表明,检测不同突变类型(10个野生型样品和12个突变型样品)的准确性,检测限(2×10 3 至2×10 4 细菌/ ml),重现性(标准偏差[SD],<0.4°C)和最低异抗性水平(40%)均符合试剂盒预设的参数。该测定可以在五种类型的实时PCR仪上运行,使用LightCycler 480 II获得的运行时间最短(105分钟)。临床研究招募了从三个地理上不同的结核病中心收集的1,096株临床分离株,包括437株对INH耐药的分离株和659株对Löwenstein-Jensen固体培养基进行传统药敏试验的INSH敏感株。 MeltPro TB / INH检测的临床敏感性和特异性分别为90.8%和96.4%。 DNA测序分析表明,除了5个突变体不在MeltPro分析的检测范围外,两种方法之间的一致性率为99.1%(457/461)。在检测到的26种突变类型中,katG S315T(AGC→ACC),inhA -15C→T,katG S315N(AGC→AAC)和ahpC启动子-10C→T占90%以上。总体而言,MeltPro TB / INH测定法是检测临床分离株中INH耐药性的可靠且快速的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号