The relative value of routine anaerobic blood culture for recovery of organisms and identification of episodes of bloodstream infection was assessed in a three-component, high-volume blood culture system which employs aerobic and anaerobic bottles of BacT/Alert (Organon-Teknika, Durham, N.C.) and aerobic cultures of Isolator (Wampole Laboratories, Cranbury, N.J.). The results of 5,595 blood culture sets from patients with suspected bloodstream infection were analyzed. Compared with either the aerobic BacT/Alert bottle or aerobic culture of Isolator, the BacT/Alert anaerobic bottle recovered significantly fewer isolates (242 versus 294, P < 0.05; 242 versus 298, P < 0.05) but did not detect significantly fewer episodes of bloodstream infection (141 versus 157, P > 0.05; 141 versus 147, P > 0.05). The BacT/Alert anaerobic bottle recovered significantly more isolates of obligately anaerobic bacteria (16 versus 4, P < 0.05; 16 versus 0, P < 0.05) and detected significantly more episodes of bloodstream infection caused by obligately anaerobic bacteria (10 versus 3, P < 0.05; 10 versus 0, P < 0.05) than either the aerobic bottle of BacT/Alert or the aerobic culture of Isolator. The combination of the BacT/Alert anaerobic bottle and the aerobic culture of Isolator recovered as may isolates (374 versus 377) and detected as many episodes of bloodstream infection (194 versus 191) as the combination of the aerobic bottle of BacT/Alert and the aerobic culture of Isolator, and both of these combinations identified at least 8% more isolates and detected at least 3% more bloodstream infections than the combination of the BacT/Alert aerobic and anaerobic bottles. Further analysis of the data revealed that the utility of the BacT/Alert anaerobic bottle, especially when combined with the aerobic culture of Isolator, resulted from not only enhanced recovery of obligately anaerobic bacteria but also effective recovery of facultatively anaerobic bacteria. These results demonstrate the utility of the anaerobic BacT/Alert bottle for detecting bloodstream infection caused by either facultatively anaerobic bacteria or obligately anaerobic bacteria and support the routine inclusion of anaerobic blood culture in the three-component blood culture system used in our hospital.
机译:常规厌氧血培养对生物体恢复和血流感染发作识别的相对价值是在三组分,大容量血培养系统中评估的,该系统采用BacT / Alert有氧和厌氧瓶(Organon-Teknika,Durham, NC)和隔离器的有氧培养(Wampole Laboratories,Cranbury,NJ)。分析了疑似血液感染患者的5595套血液培养物的结果。与好氧的BacT / Alert瓶或隔离器的好氧培养相比,BacT / Alert的厌氧瓶回收的分离株明显减少(242对294,P <0.05; 242对298,P <0.05),但未检测到明显减少的分离株。血液感染(141 vs 157,P> 0.05; 141 vs 147,P> 0.05)。 BacT / Alert厌氧瓶可回收更多分离的专性厌氧细菌(16对4,P <0.05; 16对0,P <0.05),并检测到更多由专性厌氧细菌引起的血流感染发作(10对3,P <0.05;相对于BacT / Alert好氧瓶或隔离器的好氧培养物,P <0.05; 10对0,P <0.05)。 BacT / Alert厌氧瓶和隔离器的有氧培养物的组合可以分离出(374比377),并检测出与BacT / Alert需氧瓶和BacT / Alert有氧瓶的组合一样多的血液感染发作(194和191)。隔离器的好氧培养,这两种组合比BacT / Alert好氧和厌氧瓶组合识别出至少8%的分离株,并检测出至少3%的血液感染。数据的进一步分析表明,BacT / Alert厌氧瓶的实用性,特别是与隔离器的好氧培养相结合时,不仅是由于专性厌氧细菌的回收率提高,而且是兼性厌氧细菌的有效回收率所致。这些结果证明了厌氧BacT / Alert瓶在检测由兼性厌氧细菌或专性厌氧细菌引起的血流感染中的实用性,并支持在我们医院使用的三成分血液培养系统中常规包括厌氧血液培养。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号