首页> 美国卫生研究院文献>Thorax >Reliability of a commercially available threshold loading device in healthy subjects and in patients with chronic obstructive pulmonary disease.
【2h】

Reliability of a commercially available threshold loading device in healthy subjects and in patients with chronic obstructive pulmonary disease.

机译:市场上可买到的阈值加载装置在健康受试者和慢性阻塞性肺疾病患者中的可靠性。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

BACKGROUND: Threshold loading with the Nickerson and Keens' device is frequently applied in the training and assessment of inspiratory muscles. However, this equipment is not easily applied in clinical practice and training. A study was therefore designed to investigate the accuracy and reliability of the Threshold, a commercially available threshold loading device. METHODS: The resolution (accuracy) of the system was determined by measuring variation of pressure and flow during one minute in an experimental setup. The reproducibility and flow independence were then determined during threshold loading at six different inspiratory loads between 25% and 50% maximal inspiratory pressure (PImax) in 10 patients with chronic obstructive pulmonary disease (COPD) and eight healthy subjects. RESULTS: In the first experiment the mean variation of the sustained pressure for all loads was 1.7%. The mean coefficients of variation for pressure and flow measurements were 0.2% and 3%, respectively. In the second experiment the healthy subjects showed mean coefficients of variation for pressure and flow of 0.8% and 20.5%, respectively, and the patients showed mean coefficients of variation of 0.6% and 14.5%, respectively. CONCLUSIONS: During the in vitro experiment as well as during the experiments in patients with COPD and in healthy subjects only small variations in pressure were observed despite large variations in flow. The Threshold is a reliable and reproducible device for loading inspiratory muscles in patients with COPD as well as in healthy subjects.
机译:背景:使用尼克森和基恩斯的设备进行阈值加载经常用于训练和评估吸气肌肉。但是,这种设备不容易在临床实践和培训中使用。因此,设计了一项研究来研究Threshold(一种可商购的阈值加载设备)的准确性和可靠性。方法:在实验装置中,通过测量一分钟内压力和流量的变化来确定系统的分辨率(准确性)。然后,在10名慢性阻塞性肺疾病(COPD)患者和8名健康受试者的阈值负荷期间,在最大吸气压力(PImax)在25%和50%之间的六种不同吸气负荷下确定阈值负荷下的重现性和流量独立性。结果:在第一个实验中,所有载荷下持续压力的平均变化为1.7%。压力和流量测量的平均变化系数分别为0.2%和3%。在第二个实验中,健康受试者的压力和流量平均变异系数分别为0.8%和20.5%,患者的平均变异系数分别为0.6%和14.5%。结论:在体外实验以及COPD患者和健康受试者的实验过程中,尽管流量变化很大,但观察到的压力变化很小。该阈值是一种可靠且可复制的设备,用于在COPD患者以及健康受试者中加载吸气肌肉。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号