Safety and Effectiveness of a Longer Focal Beam and Burst Duration in Ultrasonic Propulsion for Repositioning Urinary Stones and Fragments

机译:超声波推进中更长的聚焦光束和爆裂持续时间的安全性和有效性用于重新定位尿路结石和碎片

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Purpose: In the first-in-human trial of ultrasonic propulsion, subjects passed collections of residual stone fragments repositioned with a C5-2 probe. Here, effectiveness and safety in moving multiple fragments are compared between the C5-2 and a custom (SC-50) probe that produces a longer focal beam and burst duration.>Materials and Methods: Effectiveness was quantified by the number of stones expelled from a calyx phantom consisting of a 30-mm deep, water-filled well in a block of tissue mimicking material. Each probe was positioned below the phantom to move stones against gravity. Single propulsion bursts of 50 ms or 3 s duration were applied to three separate targets: 10 fragments of 2 different sizes (1–2 and 2–3 mm) and a single 4 × 7 mm human stone. Safety studies consisted of porcine kidneys exposed to an extreme dose of 10-minute burst duration, including a 7-day survival study and acute studies with surgically implanted stones.>Results: Although successful in the clinical trial, the shorter focal beam and maximum 50 ms burst duration of the C5-2 probe moved stones, but did not expel any stones from the phantom's 30-mm deep calyx. The results were similar with the SC-50 probe under the same 50 ms burst duration. Longer (3 s) bursts available with the SC-50 probe expelled all stones at both 4.5 and 9.5 cm “skin-to-stone” depths with lower probe heating compared to the C5-2. No abnormal behavior, urine chemistry, serum chemistry, or histological findings were observed within the kidney or surrounding tissues for the 10 min burst duration used in the animal studies.>Conclusions: A longer focal beam and burst duration improved expulsion of a stone and multiple stone fragments from a phantom over a broad range of clinically relevant penetration depths and did not cause kidney injury in animal studies.
机译:>目的:在超声波推进的首次人体试验中,受试者通过了用C5-2探针重新定位的残留结石碎片的收集。在此,我们比较了C5-2和定制的(SC-50)探针在移动多个碎片时的有效性和安全性,该探针产生更长的焦距和爆裂持续时间。>材料和方法:从花萼模体排出的结石数量,该花体模由一块30毫米深,充满水的小孔组成,该小孔由一块组织模仿材料制成。每个探针都放置在体模下面,以抵抗重力移动石头。将50 ms或3 s持续时间的单个推进脉冲应用于三个单独的目标:10个2个不同大小的碎片(1-2和2-3 mm)和一块4×7 mm的人类石头。安全性研究包括暴露于10分钟极端剂量的猪肾脏,包括7天生存期研究和外科手术结石的急性研究。>结果:尽管在临床试验中取得了成功,焦距更短,C5-2探针最大移动持续时间为50毫秒,可移动结石,但不会从幻影的30毫米深的花萼中排出任何结石。在相同的50毫秒脉冲持续时间下,结果与SC-50探头相似。与C5-2相比,SC-50探头可提供更长(3 s)的爆发力,以4.5至9.5厘米(厘米)的“皮肤对石头”深度将所有结石排出,并且探头发热量更低。在动物研究中使用的爆裂持续时间10分钟内,未在肾脏或周围组织内观察到异常行为,尿液化学,血清化学或组织学发现。>结论:更长的焦距和爆裂持续时间得到改善在广泛的临床相关穿透深度范围内从幻影中逐出一块石头和多块石头碎片,并且在动物研究中未引起肾脏损伤。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号