首页> 美国卫生研究院文献>Acta Orthopaedica >A 2-year RSA study of the Vanguard CR total knee system: A randomized controlled trial comparing patient-specific positioning guides with conventional technique
【2h】

A 2-year RSA study of the Vanguard CR total knee system: A randomized controlled trial comparing patient-specific positioning guides with conventional technique

机译:对Vanguard CR全膝关节系统进行为期2年的RSA研究:将针对患者的定位指南与传统技术进行比较的随机对照试验

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background and purpose — There is some concern regarding the revision rate of the Vanguard CR TKA in 1 registry, and the literature is ambiguous about the efficacy of patient-specific positioning guides (PSPGs). The objective of this study was to investigate the stability of the cemented Vanguard CR Total Knee using 2 different surgical techniques. Our hypothesis was that there is no difference in migration when implanting the Vanguard CR with either PSPGs or conventional technique. We hereby present a randomized controlled trial of 2-year follow-up with radiostereometric analysis (RSA).>Patients and methods — 40 TKAs were performed between 2011 and 2013 with either PSPGs or the conventional technique and 22 of these were investigated with RSA.>Results — The PSPG (8 knees) and the conventional (14 knees) groups had a mean maximum total point motion (MTPM) (95% CI) of 0.83 (0.48–1.18) vs. 0.70 (0.43–0.97) mm, 1.03 (0.60–1.43) vs. 0.86 (0.53–1.19), and 1.46 (1.07–1.85) vs. 0.80 (0.52–1.43) at 3, 12, and 24 months respectively (p = 0.1). 5 implants had either an MTPM >1.6 mm at 12 months and/or a migration of more than 0.2 mm between 1- and 2-year follow-ups. 2 of these also had a peripheral subsidence of more than 0.6 mm at 2 years.>Interpretation — 5 implants (3 in the PSPG group) were found to be at risk of later aseptic loosening. The PSPG group continuously migrated between 12 and 24 months. The conventional group had an initial high migration between postoperative and 3 months, but seemed more stable after 1 year. Although the difference was not statistically significant, we think the migration in the PSPG group is of some concern.
机译:>背景和目的-1个注册表中Vanguard CR TKA的修订率令人担忧,有关患者专用定位指南(PSPG)疗效的文献尚不明确。这项研究的目的是使用两种不同的外科手术技术来研究骨水泥Vanguard CR全膝关节的稳定性。我们的假设是,用PSPG或常规技术植入Vanguard CR时,迁移没有差异。 >患者和方法-在2011年至2013年之间,采用PSPG或常规技术进行了40例TKA,其中22例采用了PSPG或常规技术。 >结果 — PSPG组(8膝)和常规组(14膝)的平均最大总点运动(MTPM)(95%CI)为0.83(0.48–1.18) )分别在3、12和24个月时分别为0.70(0.43-0.97)毫米,1.03(0.60-1.43)与0.86(0.53-1.19)和1.46(1.07-1.85)与0.80(0.52-1.43) (p = 0.1)。 5个植入物在12个月时的MTPM大于1.6mm,和/或在1年和2年的随访中迁移大于0.2mm。其中有2个在2年时的周边沉降也超过0.6mm。>解释-发现5个植入物(PSPG组中有3个)有随后无菌性松动的风险。 PSPG组持续迁移了12到24个月。常规组在术后至3个月之间开始出现高迁移,但在1年后似乎更加稳定。尽管差异在统计上并不显着,但我们认为PSPG组中的迁移值得关注。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号