首页> 美国卫生研究院文献>World Journal of Gastroenterology >Contrast-enhanced sonography versus biopsy for the differential diagnosis of thrombosis in hepatocellular carcinoma patients
【2h】

Contrast-enhanced sonography versus biopsy for the differential diagnosis of thrombosis in hepatocellular carcinoma patients

机译:超声造影与活检对比对肝细胞癌患者血栓形成的鉴别诊断

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

AIM: To clarify which method has accuracy: 2nd generation contrast-enhanced ultrasound or biopsy of portal vein thrombus in the differential diagnosis of portal vein thrombosis.METHODS: One hundred and eighty-six patients with hepatocellular carcinoma and portal vein thrombosis underwent in blinded fashion a 2nd generation contrast-enhanced ultrasound and biopsy of portal vein thrombus; both results were examined on the basis of the follow-up of patients compared to reference-standard.RESULTS: One hundred and eight patients completed the study. Benign thrombosis on 2nd generation contrast-enhanced ultrasound was characterised by progressive hypoenhancing of the thrombus; in malignant portal vein thrombosis there was a precocious homogeneous enhancement of the thrombus. On follow-up there were 50 of 108 patients with benign thrombosis: all were correctly diagnosed by both methods. There were 58 of 108 patients with malignant thrombosis: amongst these, 52 were correctly diagnosed by both methods, the remainder did not present malignant cells on portal vein thrombus biopsy and showed on 2nd generation contrast-enhanced ultrasound an inhomogeneous enhancement pattern. A new biopsy during the follow-up, guided to the area of thrombus that showed up on 2nd generation contrast-enhanced ultrasound, demonstrated an enhancing pattern indicating malignant cells.CONCLUSION: In patients with hepatocellular carcinoma complicated by portal vein thrombosis, 2nd generation contrast-enhanced ultrasound of portal vein thrombus is very useful in assessing the benign or malignant nature of the thrombus. Puncture biopsy of thrombus is usually accurate but presents some sampling errors, so, when pathological results are required, 2nd generation contrast-enhanced ultrasound could guide the sampling needle to the correct area of the thrombus.
机译:目的:阐明哪种方法准确:第二代超声造影或门静脉血栓活检在门静脉血栓形成的鉴别诊断中的应用方法:186例肝细胞癌和门静脉血栓形成患者以盲法进行第二代超声造影和门静脉血栓活检;结果:根据参考标准的患者随访资料进行检查。结果:108位患者完成了研究。在第二代造影剂超声检查中,良性血栓形成的特征是血栓进行性增强。在恶性门静脉血栓形成中,血栓的早熟均一性增强。随访中108例良性血栓形成患者中有50例:两种方法均能正确诊断。 108例恶性血栓形成患者中有58例:其中有52例均通过两种方法均被正确诊断,其余在门静脉血栓活检中未出现恶性细胞,并且在第二代造影剂超声检查中显示出不均匀的增强模式。随访期间,新的活检针对第二代造影剂超声显示的血栓区域,显示出指示恶性细胞的增强模式。结论:在肝细胞癌并发门静脉血栓形成的患者中,第二代造影剂增强型门静脉血栓超声对评估血栓的良性或恶性非常有用。血栓穿刺活检通常是准确的,但存在一些取样误差,因此,当需要病理结果时,第二代对比增强超声可以将取样针引导到血栓的正确区域。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号