摘要

Insulin sensitivity (SI) estimation has numerous uses in medical and clinical situations. However, highresolution tests that are useful for clinical diagnosis and monitoring are often too intensive, long and costly for regular use. Simpler tests that mitigate these issues are not accurate enough for many clinical diagnostic or monitoring scenarios. The gap between these tests presents an opportunity for new approaches. The quick dynamic insulin sensitivity test (DISTq) utilises the model-based DIST test protocol and a series of population estimates to eliminate the need for insulin or C-peptide assays to enable a high resolution, low-intensity, real-time evaluation of SI. The method predicts patient specific insulin responses to the DIST test protocol with enough accuracy to yield a useful clinical insulin sensitivity metric for monitoring of diabetes therapy. The DISTq method replicated the findings of the fully sampled DIST test without the use of insulin or C-peptide assays. Correlations of the resulting SI values was R=0.91. The method was also compared to the euglycaemic hyperinsulinaemic clamp (EIC) in an in-silico Monte-Carlo analysis and showed a good ability to re-evaluate SIEIC (R=0.89), compared to the fully sampled DIST (R=0.98) Population-derived parameter estimates using a-posteriori population-based functions derived from DIST test data enables the simulation of insulin profiles that are sufficiently accurate to estimate SI to a relatively high precision. Thus, costly insulin and C-peptide assays are not necessary to obtain an accurate, but inexpensive, real-time estimate of insulin sensitivity. This estimate has enough resolution for SI prediction and monitoring of response to therapy. In borderline cases, re-evaluation of stored (frozen) blood samples for insulin and C-peptide would enable greater accuracy where necessary, enabling a hierarchy of tests in an economical fashion.
机译:胰岛素敏感性(SI)估计在医学和临床情况中有许多用途。然而,对于临床诊断和监测有用的高分辨率测试对于常规使用而言通常过于密集,漫长且昂贵。缓解这些问题的简单测试对于许多临床诊断或监测方案而言不够准确。这些测试之间的差距为新方法提供了机会。快速动态胰岛素敏感性测试(DISTq)利用基于模型的DIST测试协议和一系列人群估计值,从而无需进行胰岛素或C肽测定,从而可以对SI进行高分辨率,低强度,实时评估。该方法以足够的准确性预测患者对DIST测试规程的胰岛素特异性反应,以产生用于监测糖尿病治疗的有用的临床胰岛素敏感性指标。 DISTq方法无需使用胰岛素或C肽测定法即可复制完全采样DIST测试的结果。所得SI值的相关性为R = 0.91。在计算机内蒙特卡洛分析中,该方法还与正常血糖高胰岛素钳夹(EIC)进行了比较,与完全采样的DIST(R = 0.98)人群相比,该方法具有很好的重新评估SIEIC的能力(R = 0.89)。使用从DIST测试数据得出的基于后验群体的函数得出的参数估计值,可以模拟足够准确的胰岛素曲线,以相对较高的精度估计SI。因此,无需进行昂贵的胰岛素和C肽测定即可获得准确但便宜的实时胰岛素敏感性估计值。该估计值具有足够的分辨率,可用于SI预测和监测对治疗的反应。在临界情况下,对储存(冻结)的血液样本中的胰岛素和C肽进行重新评估将在必要时实现更高的准确性,从而以经济的方式实现测试的层次化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号