Reliability of Glutamate Quantification in Human Nucleus Accumbens Using Proton Magnetic Resonance Spectroscopy at a 70-cm Wide-Bore Clinical 3T MRI System

机译:在70厘米宽口径3T MRI系统中使用质子磁共振波谱对人伏隔核中谷氨酸定量的可靠性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The human nucleus accumbens is a challenging region to study using proton magnetic resonance spectroscopy (1H-MRS) on a 70-cm wide-bore clinical 3T MRI system. The aim of this study was to investigate the reliability for quantitative measurement of glutamate concentration in the nucleus accumbens using a 70-cm wide-bore clinical 3T MRI. 1H-MRS of the nucleus accumbens was acquired using the Point-Resolved Spectroscopic Sequence (PRESS) with echo time of 40 ms from 10 healthy volunteers (5 female; age range: 18–30 years) on two separate visits (a baseline, and 1-month time point). The Java-based Magnetic Resonance User Interface (jMRUI) software package was used to quantitatively measure the absolute metabolite concentrations. The test-retest reliability and reproducibility were assessed using intraclass correlations coefficients (ICC), and coefficients of variation (CV). Glutamate concentrations were similar across visits (P = 0.832). Reproducibility measures for all metabolites were good with CV ranging from 7.8 to 14.0%. The ICC values of all metabolites for the intra-class measures were excellent (ICC > 0.8), except that the reliability for Glx (glutamate + glutamine) was good (ICC = 0.768). Pearson correlations for all metabolites were all highly significant (r = 0.636–0.788, P < 0.05). In conclusion, the short-echo-time PRESS can reliably obtain high quality glutamate spectrum from a ~3.4 cm3 voxel of the nucleus accumbens using a 70-cm wide-bore clinical 3T MRI.
机译:在70厘米宽的临床3T MRI系统上使用质子磁共振波谱( 1 H-MRS)研究人伏伏核是一个具有挑战性的领域。这项研究的目的是调查使用70厘米宽口径临床3T MRI定量测量伏隔核中谷氨酸浓度的可靠性。使用点分辨光谱序列(PRESS)从10位健康志愿者(5位女性;年龄范围:18–30岁)的回波时间为40 ms的伏隔核中获取 1 H-MRS。两次单独的访问(基准时间和1个月的时间点)。基于Java的磁共振用户界面(jMRUI)软件包用于定量测量绝对代谢物浓度。使用组内相关系数(ICC)和变异系数(CV)评估重测信度和重现性。每次就诊时谷氨酸盐浓度相似(P = 0.832)。所有代谢物的重现性指标均良好,CV为7.8%至14.0%。类内测量的所有代谢物的ICC值均极佳(ICC> 0.8),但Glx(谷氨酸+谷氨酰胺)的可靠性良好(ICC = 0.768)。所有代谢产物的皮尔逊相关性均非常显着(r = 0.636–0.788,P <0.05)。总之,使用70厘米宽口径临床3T MRI,短回波PRESS可以可靠地从伏隔核的〜3.4 cm 3 体素中获得高质量的谷氨酸谱。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号