Comparative Analysis of the Equivital EQ02 Lifemonitor with Holter Ambulatory ECG Device for Continuous Measurement of ECG Heart Rate and Heart Rate Variability: A Validation Study for Precision and Accuracy

机译:用于动态测量心电图心率和心率变异性的等效动态EQ02生命监测器与动态心电图ECG装置的比较分析:精度和准确性的验证研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: The Equivital (EQ02) is a multi-parameter telemetric device offering both real-time and/or retrospective, synchronized monitoring of ECG, HR, and HRV, respiration, activity, and temperature. Unlike the Holter, which is the gold standard for continuous ECG measurement, EQO2 continuously monitors ECG via electrodes interwoven in the textile of a wearable belt.>Objective: To compare EQ02 with the Holter for continuous home measurement of ECG, heart rate (HR), and heart rate variability (HRV).>Methods: Eighteen healthy participants wore, simultaneously for 24 h, the Holter and EQ02 monitors. Per participant, averaged HR, and HRV per 5 min from the two devices were compared using Pearson correlation, paired T-test, and Bland-Altman analyses. Accuracy and precision metrics included mean absolute relative difference (MARD).>Results: Artifact content of EQ02 data varied widely between (range 1.93–56.45%) and within (range 0.75–9.61%) participants. Comparing the EQ02 to the Holter, the Pearson correlations were respectively 0.724, 0.955, and 0.997 for datasets containing all data and data with < 50 or < 20% artifacts respectively. For datasets containing respectively all data, data with < 50, or < 20% artifacts, bias estimated by Bland-Altman analysis was −2.8, −1.0, and −0.8 beats per minute and 24 h MARD was 7.08, 3.01, and 1.5. After selecting a 3-h stretch of data containing 1.15% artifacts, Pearson correlation was 0.786 for HRV measured as standard deviation of NN intervals (SDNN).>Conclusions: Although the EQ02 can accurately measure ECG and HRV, its accuracy and precision is highly dependent on artifact content. This is a limitation for clinical use in individual patients. However, the advantages of the EQ02 (ability to simultaneously monitor several physiologic parameters) may outweigh its disadvantages (higher artifact load) for research purposes and/ or for home monitoring in larger groups of study participants. Further studies can be aimed at minimizing the artifacts.
机译:>背景: Equivital(EQ02)是一种多参数遥测设备,可实时和/或回顾性地同步监控ECG,HR和HRV,呼吸,活动和温度。与动态心电图连续测量黄金标准的动态心电图不同,EQO2通过可穿戴皮带织物中交织的电极连续监测心电图。>目的:将EQ02与动态心电图连续动态心电图家庭测量进行比较,心率(HR)和心率变异性(HRV)。>方法: 18名健康参与者同时佩戴Holter和EQ02监护仪24小时。使用Pearson相关性,配对T检验和Bland-Altman分析,比较了这两个设备的每名参与者每5分钟的平均HR和HRV。准确性和精确度指标包括平均绝对相对差(MARD)。>结果: EQ02数据的伪像含量在参与者(范围1.93–56.45%)和参与者(范围0.75–9.61%)之间差异很大。将EQ02与动态心电图进行比较,包含所有数据和分别具有<50或<20%伪像的数据的数据集的Pearson相关性分别为0.724、0.955和0.997。对于分别包含所有数据,伪影<50或<20%的数据集,通过Bland-Altman分析估计的偏差为每分钟-2.8,-1.0和-0.8节拍,而24小时MARD为7.08、3.01和1.5。选择3h包含1.15%伪像的数据后,HRV的Pearson相关系数为NN间隔(SDNN)的标准偏差,为0.786。>结论:尽管EQ02可以准确地测量ECG和HRV,它的准确性和精确度高度依赖于工件的内容。这是个别患者临床使用的限制。但是,出于研究目的和/或在较大数量的研究参与者中进行家庭监测,EQ02的优点(能够同时监视几个生理参数的能力)可能会超过其缺点(较高的伪影负荷)。进一步的研究可能旨在最大程度地减少伪影。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号