首页> 美国卫生研究院文献>Clinical Molecular Pathology >Immunological identification of Neisseria gonorrhoeae with monoclonal and polyclonal antibody coagglutination reagents.
【2h】

Immunological identification of Neisseria gonorrhoeae with monoclonal and polyclonal antibody coagglutination reagents.

机译:用单克隆和多克隆抗体共凝集试剂对淋病奈瑟菌进行免疫学鉴定。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The reliability of immunological identification of Neisseria gonorrhoeae using polyclonal and monoclonal antibody coagglutination reagents has been evaluated. When clinical isolates of neisseriae were tested in an "in use" trial the sensitivity and specificity of each reagent were similar and the overall agreement with carbohydrate utilisation was 97.9% (141/144) for the polyclonal antibody reagent and 97.2% (140/144) for the monoclonal reagent. When results of testing 13 stock cultures of N lactamica and five stock cultures of beta-lactamase producing Branhamella catarrhalis were combined with the results for clinical isolates of non-gonococcal neisseriae the agreement with carbohydrate utilisation was 86.5% (64/74) for the polyclonal reagent and 97.3% (72/74) for the monoclonal reagent: this difference is statistically significant at the 5% level. Calculation of positive and negative predictive values showed differences in the reliability of the coagglutination reagents when testing Gram negative diplococci isolated from various anatomical sites. The value and limitations of the polyclonal and monoclonal reagents were similar with respect to anogenital isolates: N gonorrhoeae was confirmed by a positive result but not excluded by a negative result. The monoclonal reagent was superior for testing throat isolates; although a negative result with either reagent confirmed Gram negative diplococci as non-gonococcal neisseriae, a positive result with the monoclonal reagent was more reliable (predictive value 93%) than a positive result with the polyclonal reagent (predictive value 86%).
机译:已经评估了使用多克隆和单克隆抗体共凝集试剂对淋病奈瑟菌进行免疫学鉴定的可靠性。当在“使用中”试验中对奈瑟菌的临床分离株进行测试时,每种试剂的敏感性和特异性均相似,对于多克隆抗体试剂,碳水化合物利用的总体一致性为97.9%(141/144),而碳水化合物利用的总体一致性为97.2%(140/144) )作为单克隆试剂。将测试的13种N乳酰胺酶原种培养物和5种产生β-内酰胺酶的卡他氏杆菌的培养物的结果与非淋球菌奈瑟氏菌临床分离物的结果相结合时,多克隆抗体的碳水化合物利用率为86.5%(64/74)试剂和单克隆试剂的97.3%(72/74):这种差异在5%的水平上具有统计学意义。阳性和阴性预测值的计算表明,在测试从各种解剖部位分离出的革兰氏阴性双球菌时,凝集试剂的可靠性存在差异。就肛门生殖器分离株而言,多克隆和单克隆试剂的价值和局限性相似:淋病奈瑟菌被阳性结果证实,但未被阴性结果排除。单克隆试剂在检测喉咙分离物方面表现优异。尽管两种试剂的阴性结果均证实革兰氏阴性双球菌为非淋球菌性奈瑟氏菌,但单克隆试剂的阳性结果(预测值93%)比多克隆试剂的阳性结果(预测值86%)更可靠。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号