Objective—To study the effects of coronary artery occlusion on the pressure-volume relations of the right ventricle.
Design—Right ventricular pressure-volume cycles were studied using conductance catheters and micromanometers in 19 subjects undergoing coronary angioplasty in a tertiary referral cardiac centre.
Results—Catheter occlusions of either the left anterior descending coronary artery or the right coronary artery were associated with a decline in stroke work (mean change (SD): left −13.3(15.8)%, p = 0.008; right −13.5(16.5)%, p = 0.04). Two patterns of change were evident: an upward shift usually associated with occlusion in the left coronary artery, and a rightward shift in the right coronary artery. In the former there was an increase in maximum ventricular volume (mean change: 3.0(2.7)%, p = 0.004) and in minimum ventricular volume (mean change: 2.3(2.7)%, p = 0.01) and a fall in peak pressure (mean change: −4.8(5.1)%, p = 0.04). In the latter there was an increase in peak pressure (mean change 9.9(16.3)%, p = 0.04) and an increase in minimum ventricular volume (mean change 3.7(5.0)%, p = 0.02) leading to a fall in stroke volume (mean change −13.3(15.8)%, p = 0.008).
Conclusions—Occlusion of the left anterior descending coronary artery or the right coronary artery is associated with a decline in right ventricular work. However, different patterns of change in indices of preload and afterload lead to different effects on overall right ventricular pump function.

Keywords: right ventricle;  pressure-volume relations;  coronary angioplasty;  conductance catheter
机译:目的—研究冠状动脉闭塞对右心室压力-容积关系的影响。
设计-使用电导导管和显微压力计研究在三级转诊中接受冠状动脉成形术的19位受试者的右心室压力-容积循环。结果-左冠状动脉前降支或右冠状动脉的导管闭塞与中风功下降有关(平均变化(SD):左-13.3(15.8)%,p = 0.008 ; right -13.5(16.5)%,p = 0.04)。明显有两种变化模式:通常与左冠状动脉闭塞有关的向上移位,以及右冠状动脉向右移位。在前者中,最大心室容积增加(平均变化:3.0(2.7)%,p = 0.004)和最小心室容积增加(平均变化:2.3(2.7)%,p = 0.01)并且峰值压力下降(平均变化:−4.8(5.1)%,p = 0.04)。在后者中,峰值压力增加(平均变化9.9(16.3)%,p = 0.04)和最小心室容积增加(平均变化3.7(5.0)%,p = 0.02)导致中风量下降(平均变化-13.3(15.8)%,p = 0.008)。
结论-左冠状动脉前降支或右冠状动脉闭塞与右心室功下降有关。然而,前负荷和后负荷指标变化的不同模式对右心室泵的整体功能产生不同的影响。

压力-体积关系;冠状动脉成形术电导导管