首页> 外文期刊>Heart >Right ventricular dysfunction during coronary artery occlusion: pressure-volume analysis using conductance catheters during coronary angioplasty
【24h】

Right ventricular dysfunction during coronary artery occlusion: pressure-volume analysis using conductance catheters during coronary angioplasty

机译:冠状动脉阻塞期间右心功能不全:冠状动脉成形术期间使用电导导管的压力-体积分析

获取原文
获取原文并翻译 | 示例
       

摘要

Conclusions-Occlusion of the left ante- rior descending coronary artery or the right coronary artery is associated with a decline in right ventricular work. How- ever, different patterns of change in indices of preload and afterload lead to different effects on overall right ventricu- lar pump function. Objective-To study the effects of Coronary artery occlusion on the Pressure-volume relations of the right Ventricle. Design-Right ventricular pressure- Volume cycles were studied using conduct- Ance catheters and micromanometers In 19 subjects undergoing coronary angio- Plasty in a tertiary referral cardiac Centre.
机译:结论-冠状动脉左前降支或右冠状动脉闭塞与右心室功下降有关。但是,前负荷和后负荷指数的不同变化模式对整体右心室泵功能有不同的影响。目的-研究冠状动脉阻塞对右心室压力-容积关系的影响。设计-右心室压力-容量循环使用传导导管和显微压力计在三级转诊心脏中心接受冠状动脉血管造影的19位受试者中进行了研究。