首页> 中文期刊>法医学杂志 >尿液中γ-羟基丁酸及其前体物质的检测和应用

尿液中γ-羟基丁酸及其前体物质的检测和应用

     

摘要

目的:建立尿液中γ-羟基丁酸(gamma-hydroxybutyric acid,GHB)及其前体物质1,4-丁二醇(1,4-butanediol,1,4-BD)和γ-丁内酯(gamma-butyrolactone,GBL)的液相色谱-串联质谱法(LC-MS/MS),为相关案件提供依据。方法以GHB-d6、MOR-d3为内标,尿样经甲醇沉淀蛋白后通过液相色谱分离,电喷雾离子源进行离子化,多反应监测模式对各化合物进行检测。结果 GHB及其前体物质1,4-BD、GBL的检出限分别为0.1、0.1和2μg/mL,准确度为87.6%~98.1%,日内及日间精密度均小于15%,基质效应大于80%。结论所建立的分析方法灵敏度高、简便快速、专属性强、可靠性高,可为司法鉴定实践中涉及GHB的案件提供技术支持和基础数据。%Objective To establish the m ethod to analyze γ-hydroxybutyric acid (GHB ) and its precursors 1,4-butanediol (1,4-B D ) and gam m a-butyrolactone (GBL) in urine through LC-M S/M S and provide evi-dence for related cases. Methods GHB-d6 and M O R-d3 were used as the internal standard. The urine sam ple w as separated by LC after protein precipitation w ith m ethanol. The electrospray ion source w as for ionization. E ach com pound w as detected through m ultiple-reaction m onitoring (M R M ) m ode. Results The lim its of detection of GHB and its precursors 1,4-B D and GBLwere 0.1, 0.1 and 2μg/m L. The accuracy w as 87.6% -98.1% . The intra-day and inter-day precisions were less than 15% and m atrix ef-fects were higher than 80% . Conclusion The m ethod is high sensitive, sim ple, rapid, specific and w ith high reliability. This study has provided technical support and basic data for forensic cases involving GHB .

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号