摘要

The objective of the project is to develop a model for the capacitive ultrasonic transducer described in the Ladabaum et al., [1] paper. The main element of the transducer is a metalized silicon nitride membrane suspended on a rigid support above a heavily doped silicon bulk. The cavity under the membrane is vacuumed. When a voltage is applied between the metalized membrane and the bulk, the Coulomb forces attract the membrane toward the bulk, but stress within the membrane resists the attraction. The model developed in the project is based on the lumped parameter representation of the membrane, is easy to characterize, and is suitable for small and large signal analyses.
机译:该项目的目的是为Ladabaum等人[1]论文中描述的电容超声换能器开发模型。换能器的主要元件是金属化氮化硅膜,悬浮在重掺杂硅块上方的刚性支撑上。膜下的空腔被抽成真空。当在金属化膜和主体之间施加电压时,库仑力将膜吸引向主体,但是膜内的应力阻止了吸引力。该项目开发的模型基于膜的集总参数表示,易于表征,适合于大小信号分析。