Hysteretic Behavior of HPC Column-foundation Joint Subjected to Cyclic Horizontal Loads under Constant Axial Compression

机译:恒定轴向压缩下循环水平载荷的HPC柱基础接头的滞后行为

获取原文

摘要

This paper presents a test result to find the structural capacity of Hollow-Precast Concrete (HPC) column with Head-Splice Sleeve (HSS) for the connection of bars under horizontal cyclic load. Two Half scaled HPC column specimens were made with the consideration of construction process in site. The difference between the HPC specimens is the location of HSS for bar connection. The location of the first one is in the bottom slab or foundation while the other is above the bottom slab or foundation. Reinforced concrete (RC) column also was made for the comparison. In order to evaluate the hysteretic behavior of the specimens, horizontal cyclic load was applied to the top of specimen under constant axial load. From the test, it was confirmed that the HPC columns with HSS have enough structural capacity that can be emulated to RC column. This means that the HPC column with HSS can be used in the moment resisting frame system.