This paper reports on an experimental investigation into the axial and lateral strain development of fiber reinforced polymer (FRP) confined high-strength concrete (HSC) with prestressed FRP shells. A total of 24 aramid FRP (AFRP)-confined concrete specimens were manufactured as concrete-filled FRP tubes (CFFTs) with instrumentation to measure the strain variations during application of prestress, removal of end constraints and progressive prestress losses. Prestressed CFFT specimens were prepared with three different dose rates of expansive mineral admixture to create a range of lateral prestress applied to AFRP tubes manufactured with sheet thicknesses of 0.2 or 0.3 mm/ply and referred to as lightly- or well-confined, respectively. In addition to these three levels of prestress, non-prestressed companion specimens were manufactured and tested to determine baseline performance. The experimental results from this study indicate that lateral prestressing of CFFTs manufactured with HSC can be achieved by varying the expansive mineral admixture dose rate with a lateral prestress of up to 7.3 MPa recorded in this study. Significant strain variations were measured during removal of the end constraints with up to 700 microstrain recorded in the axial direction. Finally, the measurement of prestress losses for the month following prestress application revealed minimal progressive losses, with only 250 and 100 με recorded for the axial and hoop strains, respectively.
机译:本文报告了纤维增强聚合物(FRP)轴向和横向应变发育的实验研究局限性的高强度混凝土(HSC)与预应力FRP壳。总共24个芳族芳纶FRP(AFRP) - 综合的混凝土样本作为混凝土填充的FRP管(CFFTS),具有仪器,以测量预应力施用期间的应变变化,删除最终限制和渐进式预应力损失。预应力的CFFT标本用三种不同的膨胀矿物混合物制备,以产生一系列侧向预应力,其施加到用纸张厚度为0.2或0.3mm /级的片材厚度制造的AFRP管,并分别称为轻微或富裕。除了这三个水平的预应力外,制造并测试了非预应力伴侣标本,以确定基线性能。本研究的实验结果表明,通过在本研究中的横向预应力的膨胀矿物混合物剂量率改变膨胀的矿物混合物剂量率,可以实现与HSC制造的CFFT的横向预应力。在去除沿轴向上记录的最多700微米的微微纹理的终端约束期间测量显着的应变变化。最后,预应力申请之后的月份的预应力损失的测量揭示了最小的渐进损失,仅为轴向和环旋转菌株记录了250和100μL。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号