The objective of this work was to study the effect of some operating condition on the simultaneous removal of NO and SO_2 from simulated flue gas in the lab-scale agitated bubbling reactor. The experimental results showed that NO removal efficiency increased with the increase in the molar ratio of O_3/NO, while removal efficiency of SO_2 decreased. When absorption liquid changed from distilled water to Na_2CO_3 solution, it is observed that removal efficiencies of NO and SO_2 increase with the increase in the concentration of Na_2CO_3 solution. At 0.08 mol/L of Na_2CO_3 solution, the removal efficiencies of SO_2 and NO are 100% and 93%, respectively.
机译:这项工作的目的是研究一些操作条件对实验室搅拌反应器中的模拟烟气同时除去NO和SO_2的影响。实验结果表明,随着O_3 / NO的摩尔比的增加,没有增加去除效率,同时降低了SO_2的去除效率。当吸收液从蒸馏水变为Na_2CO_3溶液时,观察到NO和SO_2的去除效率随NA_2CO_3溶液浓度的增加而增加。在0.08mol / L的Na_2CO_3溶液中,SO_2的去除效率分别为100%和93%。