首页> 外文会议>Vacuum engineering conference >The film uniformity on magnetron sputtering with multi-workbench
【24h】

The film uniformity on magnetron sputtering with multi-workbench

机译:磁控溅射膜均匀性,用多功能垫

获取原文

摘要

This paper has presented a new type of multi-site magnetron sputtering system,which has more than one workbench. Based on the operating principle of the magnetron sputtering system with a circular plane target,a mathematical model was developed to simulate and discuss the influencing factors on the film thickness uniformity. The results of calculation and simulation showed that when the substrates are rotating axially and eccentrically,the targetsubstrate distance and eccentricity both affect the film thickness distribution. If the eccentricity is constant,the film thickness becomes thinner with increasing target-substrate distance,and the thickness uniformity tends to be improved. If the target-substrate distance is constant,the thickness uniformity becomes better then worse with increasing eccentricity. Moreover,if the substrate rotates axially and revolves round the target simultaneously,the thickness uniformity becomes better with increasing velocity ratio of axial rotation to revolution,and the effect of the thickness uniformity becomes smaller gradually if the ratio increases to a certain degree. Finally,we have taken relative experimental validation,and results comply with the simulation conclusion in general.
机译:本文提出了一种新型的多站点磁控溅射系统,具有多个工作台。基于具有圆形平面目标的磁控溅射系统的操作原理,开发了一种数学模型来模拟和讨论膜厚度均匀性的影响因素。计算和仿真结果表明,当基板轴向旋转时轴向旋转,目标距离和偏心率均影响膜厚度分布。如果偏心率是恒定的,则随着目标 - 基板距离的增加变薄,膜厚度变薄,并且趋于改善厚度均匀性。如果目标基板距离是恒定的,则随着偏心率的增加,厚度均匀性变得更好。此外,如果基板轴向旋转并同时旋转靶,则厚度均匀性随着轴向旋转的速度比与旋转的增加而变好,如果比率增加到一定程度,则厚度均匀性的效果变小。最后,我们采取了相对的实验验证,结果符合模拟结论一般。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号