首页> 外文会议>International Conference on Manufacturing Science and Engineering >Impact Studies on the Setting Styles of Stiffened Board to the Ultimate Strength of Tubular K-joints
【24h】

Impact Studies on the Setting Styles of Stiffened Board to the Ultimate Strength of Tubular K-joints

机译:对加强板设定风格的影响研究对管关节的极限强度

获取原文

摘要

This study taking the transmission steel pipe tower in the actual project as research background analyzes the mechanical property of stiffened steel tube K-joint. However, stiffened steel tube K-joint is not in the range of the code for design of steel structures GB50017-2003 of China. The corresponding solid models of finite element including K-joint in code of China and stiffened K-joint in actual project are set up to study the plastic distribution on post pipe and the influence of different setting styles of stiffened board to ultimate bearing capacity of K-joints. It was finally known that the stiffened K-joint has better mechanical property than unstiffened K-joint.
机译:本研究采用实际项目中的传动钢管塔作为研究背景分析了加强钢管k关节的力学性能。然而,加强钢管K关节不在中国钢结构设计钢结构设计规范范围内。在中国代码中包括K-Connect的有限元的相应固体模型和实际项目中加强的K-Connect,研究了塑料分布对岗位管道上的塑料分布以及不同设定风格的加强板与k的极限承载力的影响-joints。最后已知加强的k关节具有比不稳定的k关节更好的机械性能。