EMIR is a multiobject intermediate resolution near infrared (1. 0 - 2. 5 microns) spectrograph with image capabilities to be mounted on the 10 m Gran Telescopio Canarias (GTC), located on the Spanish island of La Palma. The instrument uses a HAWAII-2 infrared detector. In this paper, results of the detector characterization are presented. Apart from tests to obtain the typical figures of merit, such as readout noise, well depth, dark current, quantum efficiency or maximum pixel rate, some detailed studies have been performed to characterize the detector persistence, crosstalk between channels and the disturbing effects that appear in these detectors just after reset or after a certain time without being read. These effects and the techniques we have tried to minimize them are also presented
机译:EMIR是一种多功能中间分辨率,靠近红外(1.0-25微米)光谱仪,其具有安装在10米Gran Telescopio Canarias(GTC)的图像能力,位于La Palma的西班牙岛。仪器使用夏威夷-2红外探测器。在本文中,提出了检测器表征的结果。除了测试以获得典型的优点图,例如读出噪声,井深,暗电流,量子效率或最大像素率,已经进行了一些详细的研究,以表征探测器持久性,频道之间的串扰和出现的干扰效果在这些探测器中,在重置后或经过一段时间而不被读取。还提出了我们尝试最小化它们的效果和技术