The goal of our work is the development and practical evaluation of an objective measuring method for ultrasonograph imaging quality assessment. This complicated problemmatique was resolved using Point Spread Function (PSF ) analysis of the received signal from which a numerical value is derived. This expresses a parameter of the Lateral Resolution (LR), judged to be of paramount importance for image quality description. . We devised our own original construction of the measuring system to evaluate the method and measurement procedure.
机译:我们的作品的目标是对超声吸引力成像质量评估的客观测量方法的开发和实践评价。使用点扩展功能(PSF)分析来解决这种复杂的问题,从该点扩展函数(PSF)分析来自该分析信号的衍生数值。这表达了横向分辨率(LR)的参数,判断为对图像质量描述至关重要的重要性。 。我们设计了自己的原始结构的测量系统来评估方法和测量程序。