A distributed feedback (DFB) laser diode emitting at 785 nm was used as light source for Raman spectroscopy. An in situ surface enhanced Raman spectroscopic (SERS) sensor was developed to detect polycyclic aromatic hydrocarbons (PAHs) in marine environment at concentration levels down to nmol/l. The DFB diode used in our SERS experiments had an output power of 150 mW at 785 nm and a spectral linewidth of 3 MHz. The wavelength stability of this laser was ?0.004 nm over 12 hours. A side mode suppression ratio up to 45 dB was determined. For trace detection of chemicals in marine environment, SERS active substrates were employed based on silver colloids encapsulated in a sol-gel derived matrix. The resulting spectra and a limit of detection (LOD) of phenathrene (34 nmol/l) as an example for PAHs in seawater are presented. A concentration of 1 nmol/l of pyrene was detected.
机译:分布式反馈(DFB)激光二极管在785nm处发射作为拉曼光谱的光源。开发出原位表面增强拉曼光谱(SERS)传感器以在浓度水平下检测越野环境中的多环芳烃(PAH)至Nmol / L.我们SERS实验中使用的DFB二极管的输出功率为150mW,785 nm,光谱线宽为3 MHz。该激光的波长稳定性在12小时内为0.004nm。确定侧面模式抑制比高达45dB。对于痕量海洋环境中的化学物质的痕量检测,基于包封在溶胶 - 凝胶衍生基质中的银胶体的SERS活性底物。提出了苯甲烯(34nmol / L)作为海水中PAHS的实例的所得光谱和检测极限(LOD)。检测到浓度为1nmol / L的芘。