首页> 外文会议>CIRP Conference on Modelling of Machining Operations >Comparison of bone temperature elevation in drilling of human, bovine and porcine bone
【24h】

Comparison of bone temperature elevation in drilling of human, bovine and porcine bone

机译:钻孔钻孔骨膜升高的比较

获取原文

摘要

This paper compares the maximum temperature elevation in human, bovine and porcine bone corresponding to the drilling rotational speed from 1,000 to 10,000 rev/min. For this purpose, we perform drilling simulation using human, bovine and porcine bone models combined with experimental validation process. We demonstrate numerically and experimentally that bovine bone can mimic the human bone in terms of temperature elevation in bone drilling (0.49 - 1.15% error). The increasing rotational speed gives rise to the maximum bone temperature. The results indicate that the drilling simulation can be used to approximate the reasonably accurate output in biomedical research.
机译:本文比较了对应于1,000至10,000 Rev / min的钻井转速对应的人,牛和猪骨中的最高温度升高。为此,我们使用与实验验证过程相结合的人,牛和猪骨模型进行钻探模拟。我们在数值上证明,实际上,牛骨可以在骨钻的温度升高方面模仿人骨(0.49-1.15%误差)。增加的转速产生了最大的骨温。结果表明,钻探模拟可用于近似于生物医学研究的合理准确输出。