Plastics have been used for packaging films for a long time. Until now the development of new formulations for film applications, including process optimization, has been a time-consuming and cost-intensive process for gases like oxygen (O_2) or carbon dioxide (CO_2). By using helium (He) the permeation measurement can be accelerated from hours or days to a few minutes. Therefore a manometric measuring system for tests according to ISO 15105-1 is coupled with a mass spectrometer to determine the helium flow rate and to calculate the helium permeation rate. Due to the accelerated determination the permeation quality of monolayer and multilayer films can be measured atline. Such a system can be used to predict for example the helium permeation rate of filled polymer films. Defined quality limits for the permeation rate can be specified as well as the prompt correction of process parameters if the results do not meet the specification. This method for process control was tested on a pilot line with a corotating twin-screw extruder for monolayer films. Selected process parameters were varied iteratively without changing the material formulation to obtain the best process parameter set and thus the lowest permeation rate. Beyond that the influence of different parameters on the helium permeation rate was examined on monolayer films. The results were evaluated conventional as well as with artificial neuronal networks in order to determine the non-linear correlation between all process parameters.
机译:塑料已经用于包装薄膜很长一段时间。到目前为止,开发薄膜应用的新配方,包括过程优化,对氧气(O_2)或二氧化碳(CO_2)等气体的耗时和成本密集的方法。通过使用氦气(HE),渗透测量可以从小时或几天加速到几分钟内。因此,根据ISO 15105-1的测试测量测量系统与质谱仪耦合以确定氦流速并计算氦渗透速率。由于加速测定,可以在线测量单层和多层膜的渗透质量。这种系统可用于预测例如填充聚合物膜的氦渗透速率。如果结果不符合规范,则可以指定渗透率定义的渗透率质量限制以及处理参数的提示校正。该用于过程控制的方法在试验管线上测试,具有用于单层膜的旋芯双螺杆挤出机。选择的过程参数迭代地改变而不改变材料制剂以获得最佳工艺参数集,从而获得最低渗透率。除了在单层薄膜上检查了不同参数对氦渗透速率的影响。结果评估了常规以及人工神经网络,以确定所有工艺参数之间的非线性相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号