首页> 外文会议>International Universities' Power Engineering Conference >High Frequency Resonance of a Structure for PV panel
【24h】

High Frequency Resonance of a Structure for PV panel

机译:PV面板结构的高频共振

获取原文

摘要

A high frequency resonance of a structure for a photovoltaic (PV) panel is investigated in this paper. The resonance causes an overvoltage between a power line and a power conditioner (PC) when the structure is struck by a lightning. An effect of the structure impedance on the lightning overvoltage is clarified. The overvoltage increases when the frequency of the lightning current component is close to the resonant frequency of the structure impedance. Although the resonant frequency is an important parameter, there is no generalized formula for its estimation. The structure impedance is calculated by means of a numerical electromagnetic field analysis method, which can take into account the complex configuration of the structure for the PV panel. The transient response to lightning current of the voltage and current are transformed into the frequency domain. The ratio gives the impedance of the structure as a function of frequency. The resonant frequency is obtained from the impedance.
机译:本文研究了用于光伏(PV)面板的结构的高频共振。当结构被闪电击中时,谐振导致电源线和功率调节器(PC)之间的过电压。阐明了结构阻抗对雷电过电压的影响。当雷电电流分量的频率接近结构阻抗的谐振频率时,过电压增加。虽然谐振频率是一个重要参数,但没有全面公式估计。通过数值电磁场分析方法计算结构阻抗,这可以考虑PV面板的结构的复杂配置。对电压和电流的闪电电流的瞬态响应被变换到频域中。该比率为频率的函数提供了结构的阻抗。谐振频率是从阻抗获得的。

著录项