首页> 外文会议>American Society for Mass Spectrometry Conference on Mass Spectrometry and Allied Topics >Increased Ion Sampling Efficiency Allows Streamlining Sample Preparation for the Determination of Fluticasone Propionate in Human Plasma
【24h】

Increased Ion Sampling Efficiency Allows Streamlining Sample Preparation for the Determination of Fluticasone Propionate in Human Plasma

机译:增加离子采样效率允许在人血浆中测定丙酮丙酸酯的测定

获取原文

摘要

Taking full advantage of 6490 Triple quadrupole increased sensitivity, it was possible to streamline the workflow by relaxing the requirements on sample preparation. Sensitivity of the instrument was demonstrated with LLOQ at 5 pg/mL, corresponding to 2.5 fg abs. injected on column. The new enhanced resolution capability of the instrument may be beneficial in eliminating interference noise and therefore increasing specificity. Assay performance (correlation coefficient for calibration curves, precision and accuracy) under unit/unit and enhanced/unit resolution were similar and both within current pharmaceutical and regulatory guidelines.
机译:充分利用6490三倍的四极其提高灵敏度,可以通过放松样品制备的要求来简化工作流程。用5pg / ml的LLOQ对仪器的敏感性进行说明,对应于2.5毫级ABS。在柱上注射。仪器的新增强的分辨率能力可能是有益的消除干扰噪声,从而增加特异性。在单位/单位和增强/单位分辨率下的测定性能(校准曲线,精度和精度的相关系数)类似,在当前的制药和监管指南内。