Because of anticipated occasional hydraulic issues in an oil sands slurry pumping application, it was expected that the existing Adjustable Speed Drive (ASD) driven 2500 HP motors would be overloaded at up to 3333 HP at a slightly reduced speed from time to time. Working from factory test data, estimates were made of losses and temperature rises at the expected load points. The temperature rises were verified by testing a motor on an ASD using a "Back to Back" ASD/Motor arrangement in a specially set up off site arrangement, with the base power available being an 800 kVA alternator. In the particular application, the temperature rises were not excessive and the predicted loss of insulation life due to the higher insulation temperatures for brief times involved would not be excessive. The expected losses and temperature rises, the test setup and operation is discussed, as well as the achieved temperatures and the method of predicting loss of insulation life.
机译:由于预期的偶尔液压问题在油砂浆料泵送应用中,预计现有的可调速度驱动器(ASD)驱动的2500 HP电机将从时间略微减少3333 HP,从时刻略微降低。从工厂测试数据工作,估算损失和温度升高在预期的负荷点。通过在专门设置OFF现场布置中使用“背靠背”ASD /电机布置在ASD上测试电动机来验证温度升高,该电源可提供800 kVA交流发电机。在特定应用中,温度升高不会过度,并且由于涉及的短时间内的绝缘温度较高而预测的绝缘寿命损失不会过度。讨论了预期的损失和温度升高,测试设置和操作,以及实现的温度和预测绝缘寿命丧失的方法。