Because of anticipated occasional hydraulic issues in an oil sands slurry pumping application, it was expected that the existing adjustable speed drive (ASD)-driven 2500-hp motors would be overloaded at up to 3333 hp at a slightly reduced speed from time to time. Working from factory test data, estimates were made of losses and temperature rises at the expected load points. The temperature rises were verified by testing a motor on an ASD using a “back-to-back” ASD/motor arrangement in a specially set up off-site arrangement, with the base power available being an 800-kVA alternator. In the particular application, the temperature rises were not excessive, and the predicted loss of insulation life due to the higher insulation temperatures for brief times involved would not be excessive. The expected losses and temperature rises and the test setup and operation are discussed, as well as the achieved temperatures and the method of predicting loss of insulation life.
机译:由于在油砂泥浆泵送应用程序中偶尔会遇到液压问题,因此,预计现有的可调速驱动(ASD)驱动的2500 hp电动机将以最大3333 hp的速度过载,但速度有时会略有降低。根据工厂的测试数据,对预期负载点的损耗和温度升高进行了估算。通过使用“背对背” ASD /电动机装置(在专门设置的异地装置中)对ASD上的电动机进行测试来验证温度升高,可用的基本功率为800 kVA交流发电机。在特定的应用中,温度上升不会过分,并且由于短暂的较高绝缘温度而导致的绝缘寿命的预计损失也不会过高。讨论了预期的损耗和温升以及测试的设置和操作,以及达到的温度和预测绝缘寿命损耗的方法。