Miniaturization scaling of technology node is advancing in recent years, we are almost facing to the age of mass production for ultra-fine devices with the design rule of one-digit nanometers. Along with the scaling of technology node, distance of neighboring wires or contact plugs is inevitably reduced, and so, occurrences of short circuit defect are increasing. So far, various methods had been applied for investigating short-circuit failures. The failure analysis by SEM based electron beam absorbed current (EBAC) technique recently becomes main-stream technique among them because of its spatial resolution to determine the failure position. The DI EBAC that is the EBAC observation acquired by applying some voltage to the failure short circuit and forcing to run bias current through it was known to be effective to fix the malfunction position of failure short circuit. However, it is necessary for making the evaluation condition of the DI EBAC to have the best results. Especially, malfunction area localization for low resistive short failure is difficult by conventional technique, thus, the focus point of measurement condition is to find out DI EBAC short failure localization ability for low resistive short failure mode. In this study, several samples and measuring parameters were evaluated to find the most effective conditions in the DI EBAC. We confirmed that suitable measurement condition was possible to obtain hotspot signals in actual short failure analyses as low resistive shorted failure sample.
机译:技术节点的小型化比例是近年来推进,我们几乎面向年龄大批量生产与一个数字纳米设计规则超细设备。随着技术节点的缩放比例,相邻的引线或接触插塞的距离不可避免地降低,因此,短路缺陷的出现正在增加。到目前为止,已经申请了调查短路故障的各种方法。基于SEM的电子束的不良分析吸收的电流(EBAC)技术最近变得因为它的空间分辨率,以确定故障位置的其中主流技术。的DI EBAC即通过施加一些电压给故障短路,并迫使运行的偏置电流通过它被称为是有效的修复故障短路的故障位置获取的EBAC观察。然而,有必要使DI EBAC的评价条件,有最好的结果。特别是,对于低电阻短路故障的故障区的定位是通过常规的技术困难,因此,将测量条件的聚焦点是找出低电阻短路故障模式DI EBAC短路故障定位的能力。在这项研究中,几个样品和测量参数进行评估,以发现在DI EBAC最有效的条件。我们证实了合适的测定条件为能够获得热点信号在实际短路故障分析作为低电阻短路故障样品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号