Sputtered titanium dioxide thin film for Extended-Gate FET sensor application

机译:延伸闸FET传感器应用的溅射二氧化钛薄膜

获取原文

摘要

This paper presents an investigation on sputtered titanium dioxide (TiO2) thin film for application in the Extended-Gate Field Effect Transistor (EGFET) sensor application for pH detection. The TiO2 thin film was fabricated on conductive indium-tin oxide (ITO) covered glass by using RF Sputtering method. An EGFET proof-of-concept setup was constructed using a commercial FET as the transducer and the TiO2/ITO structure was used for the extended gate. The sensor measurement was taken using semiconductor device parametric analyzer, constant-current constant-voltage biasing interfacing circuit and data logger to obtain the sensitivity and the characteristics for output voltage with respect to time. TiO2 thin film on ITO glass as the sensing membrane was compared with a bare ITO glass substrate for the extended gate. The TiO2/ITO glass exhibited the sensitivity of 42.1 mV/pH and good linearity of 0.9997 in the sensing range pH4, pH7 and pH10 which was better than the bare ITO glass sensitivity of 31.3 mV/pH and the linearity of 0.9868.
机译:本文介绍了在延伸栅极场效应晶体管(EGFET)传感器应用中应用于PH检测的溅射二氧化钛(TiO2)薄膜的研究。通过使用RF溅射法在导电铟 - 锡氧化物(ITO)覆盖玻璃上制造TiO 2薄膜。使用商业FET构造EGFET概念装置,因为换能器,TiO2 / ITO结构用于延伸栅极。使用半导体器件参数分析仪,恒流恒压偏置接口电路和数据记录器采用传感器测量,以获得相对于时间的输出电压的灵敏度和特性。将ITO玻璃上的TiO2薄膜与传感膜相比,与伸展栅极的裸ITO玻璃基板进行比较。 TiO2 / ITO玻璃在感测范围PH4,PH7和PH10中表现出42.1mV / pH的敏感性和0.9997的良好线性,PH7和PH10优于31.3mV / pH的裸ITO玻璃敏感性和0.9868的线性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号