Evaluation of ROI methods for quantitative FDOPA PET images

机译:定量FDOPA PET图像的ROI方法的评估

获取原文

摘要

Abstract: Issues about the accuracy of ROI definition methods for FDOPA PET studies were investigated. An MRI-based ROI method and manually defined ROI method were compared using a computer simulated brain phantom and four real PET studies. The results indicate the error or discrepancy between MRI-based ROI and manually defined ROI is small ($LS $EQ 5%) at different head orientations and different noise levels. The VOI is not sensitive to the orientation, but the mid-plane ROI is also fairly reliable. !9
机译:摘要:研究了有关FDOPA PET研究中ROI定义方法准确性的问题。使用计算机模拟的脑模型和四个真实的PET研究,比较了基于MRI的ROI方法和手动定义的ROI方法。结果表明,在不同的头部方向和不同的噪声水平下,基于MRI的ROI与手动定义的ROI之间的误差或差异很小($ LS $ EQ 5%)。 VOI对方向不敏感,但是中平面ROI也相当可靠。 !9