首页> 外文会议>International offshore and polar engineering conference >Riser/Flowline Replacement Project – Riser Connector Strength Analysis
【24h】

Riser/Flowline Replacement Project – Riser Connector Strength Analysis

机译:立管/流线更换项目 - 提升器连接器强度分析

获取原文
获取外文期刊封面目录资料

摘要

Wood Group Kenny Houston was recently contracted to perform strength checks for spider buoy I-tube riser connectors since new flexible risers were to be installed. Accordingly, a FEA based strength analysis was performed to check the strength of the riser connectors using the commercial FEA software ABAQUS. The methodology and results from the strength analysis of the riser connectors is discussed in this paper. The base case for the strength analysis is in accordance with the recommendations of API RP 2RD. The Duplex and Super Duplex Itube material coupled with cathodic protection system makes the riser connectors susceptible to Hydrogen Induced Stress Cracking (HISC). Hence riser connector strength checks based on the recommendations of DNV RP F112 were also considered as a part of this check. Conclusions based on the results of these studies are presented in this paper.
机译:最近被捆绑的木头肯尼休斯顿为蜘蛛浮标I-Tube立管连接器进行实力检查,因为要安装新的灵活立管。因此,进行了基于FEA的强度分析以检查使用商业FEA软件ABAQUS的提升器连接器的强度。本文讨论了提升器连接器强度分析的方法和结果。强度分析的基本情况符合API RP 2RD的推荐。与阴极保护系统相结合的双工和超级双工速率材料使立管连接器易受氢气诱导的应力开裂(HIRC)。因此,基于DNV RP F112的建议的提升器连接器强度检查也被认为是该检查的一部分。本文提出了基于这些研究结果的结论。