This paper summarizes some findings from a study encompassing descriptions of practices and patterns seen in a regulation regime based on performance based fire safety in Norway. Performance-based fire safety engineering in Norway is usually a mixture of a pre-accepted solution with deviations. The deviations are in general motivated by restrictions related to the pre-accepted solutions. When deviations are being introduced an analysis of the consequences are usually being carried out by consultants. Such analyses are usually qualitative, not in accordance with any comprehensive procedure, and most commonly restricted to the deviation only. It does not consider the holistic fire safety level of the building. Decision-making regarding acceptable level of safety is usually done by comparing the alternative solution with another pre-accepted solution. Arguments are in most cases qualitative. As such, it could be stated that many fire safety decisions are based on subjective statements not substantiated in scientific literature, but representing experiences and gut feelings of the engineers. The concept of risk and risk analyses are not often introduced. Although this somewhat immature situation, it appears that there is some kind of consensus within the business. The rhetoric of the consultants seems to be more business-dependent than enterprise-dependent, i.e. we find the same arguments in different enterprises. Even though there is a poor understanding of measuring safety performance, the final fire safety measures and designs usually ends up quite similar.
机译:本文总结了一项研究的一些发现,包括在基于挪威的绩效的消防安全的规范制度中所见的实践和模式的描述。挪威的基于性能的消防安全工程通常是具有偏差的预接受溶液的混合物。偏差通常通过与预接受的解决方案有关的限制来激励。当偏差被引入偏差时,通常由顾问进行后果。这种分析通常是定性的,而不是根据任何综合程序,并且最常见的是仅限于偏差。它不考虑建筑物的整体防火水平。通常通过将替代解决方案与另一种预接受的解决方案进行比较来完成关于可接受的安全水平的决策。参数在大多数情况下定性。因此,可以说,许多消防安全决策是基于在科学文献中没有证实的主观陈述,而是代表工程师的经验和肠道感受。风险和风险分析的概念并不经常引入。虽然这种情况有些不成熟的情况,但似乎在业务中存在某种共识。顾问的言论似乎比企业依赖更大,即我们在不同的企业中找到了同样的论据。尽管对测量安全性能的理解差,但最终的消防安全措施和设计通常最终得到非常相似。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号