Fast pyrolysis oil is one source of renewable liquid fuels, which is promising in satisfying environmental concerns over fossil fuels. The ASTM D664 method is used to determine the acidic constituents in petroleum products, lubricants, and biodiesel requiring mixtures of 2‐propanol and toluene as solvent. The ASTM method also uses large quantities of solvents for the total acid number (TAN) determination. The ASTM D664 method has been adopted for the determination of TAN for bio‐oils data published in literature. However, the properties of fast pyrolysis bio‐oils are different from those of petroleum products and biodiesel, because bio‐oils are soluble in polar solvents and partially soluble in water whereas petroleum products and biodiesel are insoluble in water and are more non‐polar. An alternative method which is more suitable for TAN determination of pyrolysis bio‐oil has been developed and validated. Aqueous potassium hydroxide (0.1 M KOH) was used as standard titrant instead of 0.1M KOH in alcoholic solution, and acetone was used as titration solvent instead of mixtures of toluene and 2‐propanol as specified in the ASTM method. Four bio‐oil samples were analyzed for determination of TAN with the new method and the ASTM method, respectively. The results showed that TAN of bio‐oil samples obtained by the new method are in good agreement with the one obtained by the ASTM method. It was confirmed that the new method was simpler and relatively cheaper and more suitable for TAN determination of the pyrolysis oils than the ASTM D664 method.
机译:快速热解油是可再生液体燃料的一种来源,这在对化石燃料的满足环境问题上是有希望的。 ASTM D664方法用于确定石油产品,润滑剂和生物柴油中的酸性成分,需要将2-丙醇和甲苯的混合物作为溶剂。 ASTM方法还使用大量溶剂用于总酸数(TAN)测定。 ASTM D664方法已采用ASTM D664方法来确定文献中发表的生物油数据的棕褐色。然而,快速热解生物油的性质与石油产品和生物柴油的性质不同,因为生物油可溶于极性溶剂并部分溶于水,而石油产品和生物柴油在水中不溶于水并更加非极性。开发并验证了更适用于TAN测定热解生物油的替代方法。使用氢氧化钾水溶液(0.1M KOH)作为标准滴定剂代替醇溶液中的0.1M KOH,并且丙酮用作滴定溶剂,而不是ASTM方法中规定的甲苯和2-丙醇的混合物。分别分析了四种生物油样品,分别用新方法和ASTM方法测定TAN。结果表明,通过新方法获得的生物油样品的TAN与ASTM方法获得的良好一致。结果证实,新方法更简单,更便宜,更适合于比ASTM D664方法的热解油的测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号