首页> 外文会议>Instrumentation and Measurement Technology Conference (I2MTC), 2012 IEEE International >Optimization of the performances of a self-mixing velocimeter by using a Double Laser Diode Configuration
【24h】

Optimization of the performances of a self-mixing velocimeter by using a Double Laser Diode Configuration

机译:通过使用双激光二极管配置优化自混合测速仪的性能

获取原文
获取原文并翻译 | 示例

摘要

In this paper, we present a self-mixing double-head laser diode velocimeter. Several analyzes are performed to determine the optimal architecture of the double laser diode in terms of accuracy. We demonstrate that the double-head laser diode is insensitive to angle variation contrary to the single laser diode. The accuracy of the double-head laser diode sensor is verified by simulations and experiments.
机译:在本文中,我们提出了一种自混合双头激光二极管测速仪。进行了几次分析,以确定准确性方面的双激光二极管的最佳架构。我们证明,与单激光二极管相反,双头激光二极管对角度变化不敏感。通过仿真和实验验证了双头激光二极管传感器的精度。