This paper studies the conformity of the emission results of a heavy duty diesel truck from different PEMS in an environment room using a chassis dynamometer. Four kinds of PEMS are tested in this paper. The test conditions are: altitude 2400m, 2000m, temperature -7C, and normal temperature & pressure. The test cycle is C-WTVC transient test cycle. Four consecutive cycles are tested. The test results are compared with those from Horiba CVS, to analyse the conformity of the test results of CO2, CO, NOx and PN. It is shown that, for CO2, the conformity of these PEMS are high; for CO, the deviation is large; for PN, in normal condition the conformity is high while in extreme condition it is low. This research is helpful to China VI emission test.
机译:本文使用底盘测功机研究了环境室中不同PEMS重型柴油卡车排放结果的一致性。本文测试了四种PEMS。测试条件为:海拔2400m,2000m,温度-7C和常温常压。测试周期是C-WTVC瞬态测试周期。测试了四个连续的周期。将测试结果与Horiba CVS的结果进行比较,以分析CO2,CO,NOx和PN的测试结果的符合性。结果表明,对于CO2,这些PEMS的一致性很高;对于CO,偏差较大;对于PN,在正常情况下一致性较高,而在极端情况下一致性较低。这项研究对中国VI排放测试很有帮助。