首页> 外文会议>IEEE International Conference on Acoustics Speech and Signal;ICASSP 2010 >Real time tracking of exterior and interior organ surfaces using sparse sampling of the exterior surfaces
【24h】

Real time tracking of exterior and interior organ surfaces using sparse sampling of the exterior surfaces

机译:使用稀疏的外表面实时跟踪内外器官表面

获取原文

摘要

This paper presents a new algorithm for real time tracking of the exterior and interior surfaces of organs using sparse sampling of the exterior surfaces. The tracking is based on identifying subspaces in which the coefficients of spherical harmonic representations of the surfaces live. It uses pre operative CT/MRI scans during training, and needlescopic images acquired during tracking. We study different strategies for sampling the exterior organ surface using the needlescopic images and also apply the method to 3D frame interpolation. Specially, we provide (1)the first demonstration of real time interior organ surface reconstruction using sparse sampling of exterior surfaces with error rate as low as 0.095%, and (2) algorithms' application in 3D cardiac frame interpolation with error rate of only 1.15%while reducing radiation rate by 90%.
机译:本文提出了一种新的算法,可以通过稀疏采样的方式实时跟踪器官的内外表面。跟踪基于识别子空间,其中存在表面的球谐函数表示系数。它在训练过程中使用术前CT / MRI扫描,并在跟踪过程中使用针镜图像。我们研究了使用针刺图像对外部器官表面进行采样的不同策略,并将该方法应用于3D帧插值。特别地,我们提供(1)使用外部表面的稀疏采样进行实时内部器官表面重建的第一个演示,错误率低至0.095%,以及(2)算法在3D心脏帧内插中的应用,错误率仅为1.15降低90%的辐射率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号