首页> 外文会议>Holography, Interferometry, and Optical Pattern Recognition in Biomedicine >Vibration analysis of the tympanic membrane with a ventilation tube and a perforation by holography
【24h】

Vibration analysis of the tympanic membrane with a ventilation tube and a perforation by holography

机译:带通气管和穿孔的鼓膜的全息分析

获取原文
获取原文并翻译 | 示例

摘要

Abstract: For severe otitis media with effusion, insertion of a ventilation tube is performed for the purpose of ventilation of the middle ear cavity and normalization of the eustachian tubular function and middle ear mucosa. The ventilation tube is left in place for as long as several months or even a few years. However, the influence of the indwelling tube on vibration of the tympanic membrane is unknown. Therefore, the authors observed the influence by means of time-averaged holography using human tympanic membranes. The following results were obtained. After insertion of a ventilation tube, vibration pattern of the tympanic membrane was not obviously changed, but the vibration amplitude of the tympanic membrane was decreased, especially at 500 Hz. Generally speaking, the change caused by insertion of a ventilation tube was very small. Also, the vibration pattern of perforated tympanic membrane was not changed, but the vibration amplitude of perforated tympanic membrane was decreased at the low frequency area.!
机译:摘要:对于有渗出液的严重中耳炎,为了使中耳腔通气并使咽鼓管功能和中耳粘膜正常化,需要插入通气管。通风管放置时间长达数月甚至数年。但是,留置管对鼓膜振动的影响尚不清楚。因此,作者通过使用人鼓膜的平均全息照相法观察了这种影响。获得了以下结果。插入通气管后,鼓膜的振动模式没有明显改变,但是鼓膜的振动幅度减小了,特别是在500 Hz时。一般而言,由插入通气管引起的变化很小。另外,穿孔鼓膜的振动模式没有改变,但是穿孔鼓膜的振动幅度在低频区域减小。