首页> 外文会议>Emissions measurement and testing, 2009 >Factors Influencing Mass Collected During 2007 Diesel PM Filter Sampling
【24h】

Factors Influencing Mass Collected During 2007 Diesel PM Filter Sampling

机译:影响2007年柴油机PM过滤器采样过程中收集的质量的因素

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

EPA's 2007 Diesel particulate matter (DPM) standard requires a large reduction in total mass emissions. In practice, this amounts to a fractional reduction in elemental carbon emissions. The reduction is balanced by a fractional increase in the semi-volatile component, which is difficult to sample and quantify accurately at low concentrations using filter-based methods. In this work, we show how five imprecisely defined filter-sampling parameters influence the mass collected on a filter. These parameters are: dilution air quality, dilution conditions (dilution ratio and dilution air temperature), particle size classification, filter media and artifacts, and face velocity. Each factor has the potential to change the mass collected by a minimum of 5% of the standard, suggesting there is room for improvement.
机译:EPA的2007年柴油颗粒物(DPM)标准要求大幅度减少总排放量。实际上,这相当于减少了部分碳元素的排放。减少量与半挥发性成分的增加量相平衡,这很难通过基于过滤器的方法在低浓度下准确地进行采样和定量。在这项工作中,我们展示了五个定义不正确的过滤器采样参数如何影响过滤器上收集的质量。这些参数是:稀释空气质量,稀释条件(稀释比和稀释空气温度),粒度分类,过滤介质和伪影以及表面速度。每个因素都有可能将收集到的质量改变至少达到标准的5%,这表明仍有改进的空间。