Voltage sag is short duration reduction of RMS voltage and it is recognized as the most serious power quality problem for industries in Malaysia. The impact of voltage sag to the industrial equipment depends on the severity of voltage sag and the sensitivity level of equipments itself toward voltage sag. The concept of EMC for voltage sag problem call for utilities, customers, equipment manufacturer and regulators to play their role in order to minimize the impact of voltage sag by virtue of complying to SEMI F47 and MS IEC 61000 curve. This project focuses on determining the sensitivity level of selected industrial equipments by conducting Ride through Test (RTT) using CHROMA 6530 Programmable AC Source and PSL Industrial Power Corruptor. The industrial equipments selected are the production machine for Semiconductor industries (Tester Machine, Wire Bond Machines and Die Attached), Programmable Logic Controller (PLC) and Magnetic contactors. The sensitivity or Immunity level data of the selected industrial equipments against voltage sag has been established. Comparison on the sensitivity level among similar type of equipments is also performed. It is evident from the RTT results, that majority of semiconductor equipments are very sensitive to voltage sag. The RTT results for PLCs and magnetic contactor also indicate that these two equipments are very sensitive to voltage sag and establish themselves as one of the ‘weak links’ in industrial equipment system. The established sensitivity data for the industrial equipments is helpful in predicting estimated loss due to voltage sag and determining the best cost effective voltage sag mitigation solution to the industrial equipments.
机译:电压骤降​​是RMS电压持续时间短的降低,它被认为是马来西亚各行业最严重的电能质量问题。电压骤降​​对工业设备的影响取决于电压骤降的严重程度以及设备本身对电压骤降的敏感度。 EMC解决电压暂降问题的概念要求公用事业,客户,设备制造商和监管机构发挥作用,以便通过遵守SEMI F47和MS IEC 61000曲线来最大程度地降低电压暂降的影响。该项目着重于通过使用CHROMA 6530可编程交流电源和PSL工业功率腐蚀器进行穿越测试(RTT)来确定所选工业设备的灵敏度水平。所选的工业设备是用于半导体工业的生产机器(测试机,引线键合机和贴片机),可编程逻辑控制器(PLC)和电磁接触器。已经建立了所选工业设备对电压骤降的灵敏度或抗扰度数据。还对相似类型的设备之间的灵敏度进行了比较。从RTT结果可以明显看出,大多数半导体设备对电压骤降非常敏感。 PLC和电磁接触器的RTT结果还表明,这两种设备对电压骤降非常敏感,并使其成为工业设备系统中的“薄弱环节”之一。为工业设备建立的灵敏度数据有助于预测由于电压暂降而造成的估计损失,并为工业设备确定最佳的成本有效的电压暂降缓解方案。

著录项

  • 作者

    Hassan Ahmad Nizam;

  • 作者单位
  • 年度 2009
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号