首页> 外文OA文献 >Casting distortion of five-fixture supported implant frameworks fabricated on master casts
【2h】

Casting distortion of five-fixture supported implant frameworks fabricated on master casts

机译:在主模型上制造的五夹具支撑植入物框架的铸造变形

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Statement of the problem: Conventional techniques for implant framework fabricationudhave been shown to produce errors that are inconsistent with the passive-fit requirementudfor osseointegrated implant frameworks.udPurpose: The aim of this study was to assess the three-dimensional distortion inherent inudcasting of full arch, screw-retained titanium implant frameworks.udMaterials and methods: A conventional commercial laboratory one-piece casting, usingudthe lost-wax technique was used. Five wax patterns were fabricated on a die-stone castudpoured from a plaster impression of a five-fixture brass analogue. A reflex microscope wasudused to determine the three-dimensional casting error, by measuring horizontal and verticaluddistances for each wax pattern and its corresponding cast titanium framework, as well asudoffset distances from the horizontal reference plane.udResults: Significant differences were found in the amount of distortion between waxudpatterns and cast frameworks, with the castings being approximately 416 μm to 477 μmudlarger than the wax frameworks. The greatest amount of distortion occurred at the terminaludimplant abutments, and in the vertical dimension. However, there was inconsistency inudthese differences, indicating the three-dimensional nature of the overall distortion of theudcast frameworks.udConclusions: It is doubtful whether any conventionally cast framework can be made to theuddegree of accuracy required to fit passively on its abutments because of the multipleudvariables inherent in this process. It is therefore recommended that all full-arch, castudtitanium frameworks be cast in sections, or alternatively be sectioned, indexed andudsoldered before being seated intraorally.
机译:问题陈述:植入物框架制造的常规技术已证明会产生与被动配合要求不符的误差骨集成植入物框架的ud。目的:本研究的目的是评估固有的三维变形 ud材料与方法:采用传统的商业实验室一件式铸造法,采用 waste-wax技术。在由五夹具黄铜类似物的石膏模压铸而成的/浇铸的模铸石头上制作了五个蜡模。通过使用反射显微镜来确定三维铸造误差,方法是通过测量每个蜡型及其相应的铸造钛骨架的水平和垂直 uddist距离以及与水平参考平面的 udoffset距离。 ud结果:显着差异发现蜡 udpatterns和铸造框架之间的变形量,铸件大约比蜡框架大416μm至477μm ud。最大变形发生在末端种植体基台和垂直方向。但是,这些差异之间存在不一致,表明 udcast框架的整体失真具有三维性质。 ud结论:是否可以将任何常规的强制转换框架制作成适合被动适应的精确度,这令人怀疑。由于其在过程中固有的多个 udvariables,因此在其基台上。因此,建议在口内就座之前,将所有全拱形铸造钛合金框架分批铸造,或者分段,标引和焊接。

著录项

  • 作者

    Mitha Tasneem;

  • 作者单位
  • 年度 2008
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号