Fit of implant-supported fixed prostheses fabricated on master casts made from a dental stone and a dental plaster.

机译:适合由种植体支撑的固定假体在由牙石和牙膏制成的铸模上制造。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

STATEMENT OF PROBLEM: The impression and cast on which an implant-supported fixed prosthesis is fabricated must accurately reproduce the intraoral relations. PURPOSE: The fit of fixed prostheses fabricated on master casts poured in a conventional die stone and in an ultra-low-expansion plaster was investigated in vitro. MATERIAL AND METHODS: An impression was made of patient replicas with inter-implant abutment distances of 50 and 35 mm. Ten master casts were poured in a conventional die stone (Velmix, Kerr) and 10 in an ultra-low-expansion plaster (Gnathostone, Zeus). A simulated plaster fixed prosthesis was fabricated on each master cast and then returned in a random order to the appropriate patient replica. The fixed prostheses were screwed into place on one abutment with a torque of 10 Ncm. Vertical discrepancies were measured at the other abutment by an operator blinded to the cast on which the fixed prosthesis was fabricated. A 2-way analysis of variance was performed for distance and materials, and significant differences were identified with regression analysis. RESULTS: For the 50-mm inter-abutment distance, die stone master casts produced a mean vertical discrepancy of 80 microm (SD 32.50 microm). Plaster master casts produced a mean vertical discrepancy of 42.8 microm (SD 12.17 microm). The means were significantly different (P=.01). For the 35-mm inter-abutment distance, the mean vertical discrepancy produced from the die stone and plaster master casts was 84.33 microm (SD 49.9 microm) and 0 microm (SD 0), respectively. The means were significantly different (P<.001). A significant difference was found between the mean vertical seating discrepancies of fixed prostheses produced from plaster casts with inter-abutment differences of 50 mm and plaster casts with inter-abutment distances of 35 mm (P=.003). No significant differences were found between mean vertical seating discrepancies for fixed prostheses fabricated on die stone casts. CONCLUSION: In this in vitro study, master casts poured in an ultra-low-expansion plaster limited to a maximum inter-abutment dimension of 35 mm were more accurate than casts with 50-mm inter-abutment spans or those poured in a conventional die stone.
机译:问题陈述:制造植入物支撑的固定假体的印模和铸模必须准确地再现口内关系。目的:在体外研究在浇铸在常规型铸石和超低膨胀石膏中的铸模上制造的固定假体的配合情况。材料与方法:假体的种植体间基台距离分别为50和35 mm。将十个主铸模倒入常规的模具石(Velmix,Kerr)中,将十个铸模倒入超低膨胀石膏(Gnathostone,Zeus)中。在每个主模型上制作一个模拟的石膏固定假体,然后以随机顺序返回给适当的患者复制品。将固定的假体以10 Ncm的扭矩拧入一个基台上的位置。垂直差异是由操作员在另一个基台上测量的,该操作员对制作固定假体的模型不了解。对距离和材料进行了2方差分析,通过回归分析确定了显着差异。结果:对于50毫米的基台间距离,压模母模产生的平均垂直差异为80微米(标准偏差32.50微米)。石膏主铸件产生的平均垂直差异为42.8微米(SD 12.17微米)。均值有显着差异(P = .01)。对于35毫米的基台间距,由模石和石膏主铸件产生的平均垂直差异分别为84.33微米(SD 49.9微米)和0微米(SD 0)。均值显着不同(P <.001)。发现基台间间距为50 mm的石膏模型与基台间距离为35 mm的石膏模型产生的固定假体的平均垂直坐位差异(P = .003)之间存在显着差异。在铸模铸件上制作的固定假体的平均垂直坐位差异没有发现显着差异。结论:在这项体外研究中,浇铸到最大基台间最大尺寸为35 mm的超低膨胀石膏中的母模比具有50 mm桥基间跨度的铸件或浇注在常规模具中的铸件更准确。结石。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号