首页> 外文OA文献 >Comparison of Body Composition Measurements using a New Caliper, Two Established Calipers, Hydrostatic Weighing, and BodPod
【2h】

Comparison of Body Composition Measurements using a New Caliper, Two Established Calipers, Hydrostatic Weighing, and BodPod

机译:使用新卡尺,两个已建立的卡尺,静水称重和BodPod进行身体成分测量的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Purposes: (1) To compare the Lafayette Instruments (LI) skinfold caliper to the Lange (L) and Harpenden (H) calipers using a diverse subject population. (2) To determine the validity of the LI caliper in a subset of subjects by comparing body compositions from skinfold thicknesses to those measured by hydrostatic weighing (HW) and air displacement plethysmography (ADP). (3) To compare measurements obtained by experienced (EX) and inexperienced (IX) technicians using all three calipers. Methods: Skinfold measurements were performed by both EX and IX technicians using three different calipers on 21 younger (21.2 ± 1.5 yrs) and 20 older (59.2 ± 4 yrs) subjects. Body compositions were calculated using the Jackson-Pollock seven-site and three-site formulas. HW and ADP tests were performed on a subset of subjects (10 younger, 10 older). Results: No significant differences existed between LI and L or H when measurements were made by EX. Further, the LI-EX measurements were highly correlated to both H-EX and L-EX. No significant differences existed in the subgroup between LI-EX and HW or ADP. Skinfold determinations made by EX and IX were similar. Conclusions: Similar body compositions determined using LI, H, and L suggest that LI determines body composition as effectively as H and L. High correlations between the three calipers support this notion. Similar results between LI and HW/ADP subgroup suggest that the LI caliper may be a valid method of measuring body composition. Overall, performance by IX was similar to EX and suggests similar ease of use for all three calipers.
机译:目的:(1)使用不同的研究对象将拉法叶(LI)皮褶卡尺与兰格(L)和哈彭登(H)卡尺进行比较。 (2)通过比较从皮褶厚度到通过静水压(HW)和空气体积体积描记法(ADP)测量的人体成分来确定LI卡尺在部分受试者中的有效性。 (3)比较使用所有三种卡尺的经验丰富(EX)和经验不足(IX)技术人员的测量结果。方法:EX和IX技术人员使用三种不同的测径器对21位年轻(21.2±1.5岁)和20位年龄较大(59.2±4岁)的受试者进行了皮褶测量。使用Jackson-Pollock的7位和3位公式计算身体成分。硬件和ADP测试在一组受试者中进行(年龄10岁以下,年龄10岁以下)。结果:EX进行测量时,LI与L或H之间没有显着差异。此外,LI-EX测量值与H-EX和L-EX高度相关。 LI-EX与HW或ADP之间的亚组之间没有显着差异。 EX和IX做出的皮褶测定结果相似。结论:使用LI,H和L确定的相似身体成分表明LI可以像H和L一样有效地确定身体成分。这三个卡尺之间的高度相关性支持了这一观点。 LI和HW / ADP子组之间的类似结果表明,LI卡尺可能是测量身体成分的有效方法。总体而言,IX的性能与EX相似,这表明这三款卡尺的易用性相似。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号